Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0824-04770
Parcel: 126171260

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.3

Permit Number - TC-RES-0824-04770
Review Name: RESIDENTIAL SIMPLE REVIEW v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/16/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/16/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0824-04770 (3942 E SANTA BARBARA AV TUCSON, AZ 85711)
2nd Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC).

>>> The following comments were not fully addressed.
Electrical:
1. Provide a panel schedule showing wire size and OCPD of each new circuit, E3702.2. >>> Missing wire size for each new circuit.

>>> Provide an updated site-plan with the following information shown:
2. The conductors underground must comply with E3803.1 and be rated for use in a conduit in a wet location, E3803.10 i.e. THWN.
3. Designate the circuit number (that correlates to the panel schedule) at the location of each receptacle, switch, or utilization equipment, E3404.12.

Outdoor Lighting: >>> Low voltage lighting is not exempt from the Outdoor Lighting Code.
4. Show the location of all new outdoor lighting equipment.
5. Show compliance with City of Tucson Outdoor Lighting Code (OLC) with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations. Show full cutoff fixtures were located with 25 feet from the property line OLC 401.3.3. Show unshielded fixtures with a maximum of 3,000 lumens, OLC 401.4. Show lamps with a maximum of 3500K color temperature, OLC 402.1.


Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
09/16/2024 PDSD Application Completeness Express REVIEW COMPLETED