Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0824-04767
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/12/2024 | Site Zoning | APPROVED | |||
09/13/2024 | Site Engineering | NOT REQUIRED | |||
09/13/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
08/20/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0824-04767 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide a response letter on separate file with the updated construction plan set. SITE PLAN: 1. Show the location of proposed underground electrical lines R106.1.1. SECTIONS - DETAILS: 1. Provide a wall section detail with reinforced foundations for anchoring exterior framed walls with pressure treated sills including ½” anchor bolts with 7” embedment, R403.1.6. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5). The weep screed may extend with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1. ELECTRICAL PLANS: 1. Show the location of the sub-panels on the Electrical Plan with clear working space compliance, E3601.6.2 & E3705.8. 2. Show GFCI receptacle outlets in the garage, E3901.9 & E3902.2. OUTDOOR LIGHTING CODE 1. . Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
08/15/2024 | PDSD Application Completeness | REVIEW COMPLETED |