Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0824-04739
Parcel: 128112150

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0824-04739
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/14/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/14/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Please adjust drawing and resubmit for review.
Due to the length and demand the 8' section of pipe needs to be 3/4" and not 1/2". Gas Lines- Use Table G2413.4(1) (Metallic Pipe) to calculate correct required pipe sizes

building_official@tucsonaz.gov