Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0824-04625
Parcel: 134050610

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADU REVISION v.1

Permit Number - TC-RES-0824-04625
Review Name: RESIDENTIAL ADU REVISION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/09/2025 Site Engineering NOT REQUIRED
01/15/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/26/2024 Residential Building REQUIRES RESUBMIT TC-RES-0824-04625
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Facilitate a shorter back check time: provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes.

Provide a response letter on separate file with submitting the updated construction plan set.

PLANS:

1. Indicate the direction of slope for the garage slab, R309.1.
2. Provide the function of the room at the north end of the garage. Openings from a garage directly into a sleeping room are not permitted, R302.5.1.

STRUCTURAL PLANS:

1. Provide a vehicle opening beam sized for supporting live and dead structural loads (Table R602.7(3)) or provide an engineer’s calculation, design, and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1. The two 2x8 door header is undersized for supporting 44 foot trusses.

SECTIONS - DETAILS:

1 Provide a Garage wall detail showing a 6” minimum separation of exterior siding or sheathing above finished grade, R317.1 item 5 and a footing at least 12” below the undisturbed ground surface, R403.1.4. This may require a design with concrete stems for a level sill and a sloping floor.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review
01/15/2025 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-0824-04625
624 S SANTA ANA DR – R-1
Garage Addition (1st Revision, 1st Review)

TRANSMITTAL DATE: January 15, 2025

COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9

1. The proposed revision shows a 3’-0” roof overhang along the east side of the proposed garage. Per UDC Article 6.4.5.D.2.b Roof overhangs are only allowed to overhang into the required perimeter yard 2’-0”. Show the allowed 2’-0” overhang on the plot plan and provide a perimeter yard setback dimension from the southeast corner of the allowed overhang to the east property line. It appears that this setback will be less than 10’-0” and will require a Design Development Options (DDO) to be submitted and approved to reduce the side street perimeter yard setback, DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”.

2. Based on the provided plot plan the proposed garage does not run parallel to the east property line. Provide a street perimeter yard setback dimension from the southeast corner of the garage to the east property line

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
12/15/2024 PDSD Application Completeness Express REVIEW COMPLETED