Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0824-04530
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/17/2024 | Site Zoning | APPROVED | |||
| 09/23/2024 | Site Engineering | NOT REQUIRED | |||
| 09/23/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/26/2024 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0824-04530 (2444 S SAWTELLE AV TUCSON, AZ 85713) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC). 1. Provide a Roof Framing Plan showing the location and size of beams, and rafters for supporting live and dead structural loads, R804. Identify live and dead loads. Show the location and spacing between the posts. See sheet 2: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/porch_sample.pdf 2. The provided beam may be undersized, depending on the spacing of the posts. 3. Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity at each rafter to beam connection, R802.11 amended. 4. Show the ledger board against the existing framing wall and all stucco removed between the ledger and existing framing. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 08/21/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |