Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0824-04530
Parcel: 130056080

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0824-04530
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/01/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/01/2024 Residential Building PENDING ASSIGNMENT
11/01/2024 PDSD Application Completeness Express REQUIRES RESUBMIT AH - Your submittal is incomplete missing roof framing plan and a written response letter.
to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC).

1. Provide a Roof Framing Plan showing the location and size of beams, and rafters for supporting live and dead structural loads, R804. Identify live and dead loads. Show the location and spacing between the posts. See sheet 2: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/porch_sample.pdf
2. The provided beam may be undersized, depending on the spacing of the posts.
3. Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity at each rafter to beam connection, R802.11 amended.
4. Show the ledger board against the existing framing wall and all stucco removed between the ledger and existing framing.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov