Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - TC-RES-0824-04513
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/09/2024 | Site Engineering | NOT REQUIRED | |||
12/18/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
11/26/2024 | Residential Building | REQUIRES RESUBMIT | 1. Remove the proposed gray water system and notes from sheet A-4 and P-1. This is not an approved design. 2. Show all exterior lighting fixtures as "full cut-off". All proposed fixtures within 25 feet from a side property line must be shielded from horizonal emittance. |
||
12/18/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Ramiro Olivarez Planner; Zoning Review Team PROJECT: TC-RES-0824-04513 919 N ALDER AV TUCSON, AZ 85705 – R-2 Master Bedroom and Bathroom Addition (2nd Review) TRANSMITTAL DATE: 12/18/2024 This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10. 1. Previous Applicable Comment 1: The site plan should be designed to include the information as noted on the sample plot plan. On the site plan only show the individual lot and all that is required as seen in the sample plot plan. See the link below for the information that is required on the plot plan. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf . Follow up to comment 1: Per the required plot plan example #1., the plot plan should be drawn and scaled to an engineering scale of 1” = 10’-0”. 2. Comment: There is a discrepancy between the setback measurements labeled on the site plan and the setback measurements on the proposed floor plan. Clarify what the correct setback dimensions are. If the site plan setback dimensions are right, correct the Proposed floor plan setback dimensions to match the setback dimensions labeled on the site plan. 3. Previous Applicable Comment 3: Provide the total lot coverage calculations. Per UDC article 6.4.3 lot coverage shall need to include the area of a lot covered by buildings, storage areas, including dimensioned Vehicular use areas. Remove the porch square footage from the total lot coverage calculations. Porches are not to be included in total lot coverage calculations. (As noted on the sample plot plan above) Follow up to comment 3: Include the vehicular use area in the lot coverage calculation. 4. Previous Applicable Comment 3: Draw, label, and dimension the north elevation of the structure including its wall height from design grade to the top of the wall to ensure setbacks are met. Follow up to comment 4: Provide a drawn, labeled, and dimensioned north elevation of the structure addition. This is to ensure minimum setback requirements are complied with. 5. Comment: Additional comments may be forthcoming on the next review based on the proposed use for the addition and applicable use specific standards. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Provide a corrected Site plan and provide a north elevation. If you have any questions about this transmittal, please contact Ramiro Olivarez Ramiro.Olivarez@tucsonaz.gov |
||
11/06/2024 | PDSD Application Completeness | REVIEW COMPLETED |