Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.4
Permit Number - TC-RES-0824-04505
Review Name: RESIDENTIAL NEW DWELLING v.4
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/07/2024 | Site Zoning | APPROVED | |||
| 10/24/2024 | Site Engineering | NOT REQUIRED | |||
| 10/24/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/01/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0824-04505 2nd PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: Provide a response letter on separate file with the updated construction plan set. GENERAL COMMENTS : 1. Label a double breaker space for future Photo Voltaic on the panel schedule opposite end from the main/supply side, T103.9. Show the circuit space on the panel schedule (bottom spaces) rather than on the riser diagram. 2. The gray water ordinance requires a second clothes washer standpipe plumbed to an exterior wall above grade when feasible. The bathing fixture drain should not be included with this plan having the washer at an exterior wall. 3. Show compliance with the Electric Vehicle Supply Equipment Ordinance adopted by the City of Tucson Ordinance #11844 on 6/22/2021. Include a 40 ampere 240-volt dedicated branch circuit with a NEMA 14-50R receptacle for charging an electric vehicle at a proposed parking space. Show the circuit on the panel schedule. FLOOR PLAN: 1. Clearly show the location of 5/8” Type X gypsum board placed at each side of the wall between the kitchen and carport rather than at the ceiling noted on the site plan, IBC Table 721.1(2). The wall is a better option than the carport ceiling. The kitchen ceiling does not require the fire rated material. The purpose is for placing a fire barrier between dwelling units connected by the carport. MECHANICAL PLANS: 1. Provide whole-house mechanical ventilation with controlled exhaust, R303.4; N1103.6 & M1505.4. Show the minimum airflow rate setting and location of the device requiring this adjustable setting. Add a note for the 30 CFM continuous setting on sheet #7. ELECTRICAL PLANS: 1. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. Show a circuit in addition to #6. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 09/24/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |