Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0823-07695
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/01/2023 | Site Engineering | NOT REQUIRED | |||
| 09/28/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/20/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0823-07695 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: Clarify if the structure is a sleeping quarters (without kitchen) or an Accessory Dwelling Unit (ADU) which requires many alterations for compliance. An independent dwelling (ADU) requires fire spread and utility (electrical & water) separation so that one dwelling is not dependent upon another for water or electrical service. Each dwelling unit with kitchen requires a separate Pima County assigned street address after Zoning approval, R319. An impact fee payment is required for an ADU at the time of permit payment. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc. PLANS: 1. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1. SECTIONS - DETAILS: 1. Show both existing and proposed roof projections extending into the fire separation distance between dwellings with not less than one-hour fire-resistive construction on the underside, R302.1 (City of Tucson Amended). 2. Remove fire barrier openings from the roof projection underside, R302.1. Update detail #1/ A-3. 3. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5). Update detail #4/A-3. 4. Show an unvented roof assembly with all insulation at the roof including an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing as part of the total insulation requirement, R806.5 or show the attic vent opening size using 1 to 150 of attic area with insulation at the ceiling in compliance with R806.2. MECHANICAL PLANS: 1. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation with controlled exhaust, R303.4; N1103.6 & M1505.4. Show the airflow rate setting. A one bedroom dwelling under 1501 SF requires a 30 CFM continuous setting. ELECTRICAL PLANS: 1. Show new or extended interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3902.16 & 17. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 09/28/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0823-07695 5701 East Burns Street – R-1 ADU (1st Review) TRANSMITTAL DATE: September 28, 2023 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. The site is in the R-1 zone (UDC 4.7.8). An ADU is a permitted use in the R-1 zone, subject to use-specific standards 4.9.7.B.6, .8, and .9, and 6.6.3. 1. Show the five-foot-wide easement along the west lot line as depicted on the Clara Vista Subdivision Plat: https://maps-and-records.tucsonaz.gov/subdivisions/details/MP-10070&. 2. On cul-de-sac and eyebrow front lots, the minimum street yard depth may be measured from a straight line drawn between the front lot corners, except as provided in Section 6.4.5.C.2.b, Carports and Garages in Single-Family and Duplex Development. A minimum setback of 20’-0” is required between the front street lot line and the garage. A DDO may only be utilized to reduce the setback to a minimum of 18’-0” (the length of a standard parking space). Contact Georgia.Pennington@tucsonaz.gov should you have questions about the DDO process. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 09/22/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 09/01/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | Please submit a separate permit for the garage addition under "Residential Addition/Alteration". |