Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0823-07687
Parcel: 137273080

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR v.1

Permit Number - TC-RES-0823-07687
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/05/2023 Site Engineering NOT REQUIRED
09/12/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/12/2023 Light Residential Building Review (OIP) REQUIRES RESUBMIT Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. Provide a lag-bolt connection up-lift calculation demonstrating the wind load supporting capability for 115 MPH, or provide an engineer’s calculation, and sealed design, R301.1, R324.4. An IRC PV roof uplift calculator (XLS) is available on Pima County’s website. https://www.pima.gov/1069/Solar-Wind-Systems
• Provide the exact wording and location for the Photovoltaic system Warning signs and labels as required in NEC 690 and 705.12(B)(2)(3) b-c.
o “Photovoltaic System Disconnect” NEC 690.13(B)
o NEC 690 Part VI Markings – NEC 690.51-58
o NEC 690.33(E).
Contact Jamie Mason with any questions: Jamie.Mason2@tucsonaz.gov
08/31/2023 PDSD Application Completeness Express REVIEW COMPLETED