Permit Number: TC-RES-0823-07650
Parcel: 134211010

Address:
7043 E TIMROD ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR v.1

Permit Number - TC-RES-0823-07650
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/11/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/11/2023 Light Residential Building Review (OIP) REQUIRES RESUBMIT FROM: Veronica Flores
PDSD Residential Review Section

PROJECT: TC-RES-0823-07650
Installation of a 4.40 kW DC/ 3.57KW AC pv system 11 modules-
(1st Review)
(7043 E Timrod St)

TRANSMITTAL DATE: September 11th, 2023

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a Written Response Letter to each of the notated items indicating action taken. Resubmitted plans/calculations that do not contain a written Response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.

COMMENTS: Code reference, 2018 International Residential Code (IRC).

1. Provide a lag-bolt connection up-lift calculation demonstrating the wind load supporting capability, or provide an engineer’s calculation, and sealed design, R301.1, R324.4. An IRC PV roof uplift calculator (XLS) is available on Pima County’s website. https://www.pima.gov/1069/Solar-Wind-Systems

If you have any questions about this transmittal, Contact Veronica Flores by email Veronica.Flores@tucsonaz.gov
09/05/2023 Site Engineering REQUIRES RESUBMIT Project: TC-RES-0823-07650

Address: 7043 E TIMROD ST

This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.)

Please start a new FUP at our permit application web page:

https://tdc-online.tucsonaz.gov/#/home

NOTE: Documentation of a cost estimate from your contractor will be required if this project involves any reconstruction, repair, rehabilitation, structurally connected addition, or other improvement of an existing structure (including TI’s and solar). Construction of separate builds/new structures does not require a cost estimate to be provided.

Instructions:

1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record

2. Locations -> Confirm the location is accurate to the project. Click “Next”

3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next”

4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next”

5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next”

6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next”

7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next”

8. Review and Submit -> Review all information to ensure accuracy. Click “Submit”

Contact Lianne Evans at lianne.evans@tucsonaz.gov or Stephen Blood at Stephen.Blood@tucsonaz.gov if you have any questions about the FUP.
08/29/2023 PDSD Application Completeness Express REVIEW COMPLETED