Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0823-07474
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/20/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
09/20/2023 | Design Review | REQUIRES RESUBMIT | The shade frame is an unpermitted structure requiring NPZ review. A completed NPZ design package is required, and must be submitted as a request from your building permit. A checklist and instructions for an NPZ design package can be found here: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/submission-documents/special_districts_application_instructions_7.18.23.pdf After reading through the above pdf, if you have any questions please email me a gabriel.sleighter@tucsonaz.gov |
||
09/11/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-0823-07474 (111 E ADAMS ST TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). Site Plan: 1. Provide a complete Site Plans. Indicate the location and size of buildings, utility meters and utility lines, R106.1.1. Note on the plans if any utilities are being Structural Plans: 2. A shade sail greater than 200sf requires all structural documents to be prepared, sealed, signed, and dated by an Arizona registered design professional. Provide complete structural plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IRC R106.1.1, 2018 IBC section 107.1. 3. Show the posts being used to support the shade sail. Show all hardware used for attaching the posts to the foundation and to the shade sail, R106.1.1. 4. Identify all fasteners for wind loading compliance with appropriate uplift capacity, R802.11 amended. 5. Show a complete cross-section detail of the new shade structure, R106.1.1. Show the #4 rebar reinforced footing used for supporting the wind and lateral loads, R403.1. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
09/15/2023 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-RES-0823-07474 111 E Adams St– NR-2 Shade cloth addition (1st Review) TRANSMITTAL DATE: 09/15/2023 1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf This plan at a minimum shall: - Show all structures and indicate all property boundaries - Provide the height for all structures. - Show the entire parcel 2. The property is located in Feldman’s Neighborhood preservation zone (NR-2). NPZ approval is required prior to zoning approval. Resubmittal instructions: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov |
||
08/25/2023 | PDSD Application Completeness | REVIEW COMPLETED |