Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0823-07454
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/14/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/14/2023 | Historic | REQUIRES RESUBMIT | Please provide a completed Historic Demolition Documentation form (https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/historic_demolition_application_form.pdf) and the associated required items via TDC Online under the permit number. | ||
| 09/06/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0823-07454 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide an updated complete plan set with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet Zoning and other departmental requirements, conditions, and concerns before permit approval. Living Room Addition with Basement, Loft and Deck for 940 N LONGFELLOW AV. GENERAL REQUIREMENTS: Provide a complete construction plan set in a single file with all support documents placed in separate files such as truss plans and a Manual J, D & S report. A dwelling unit (casita with a kitchen) requires a separate permit. An ADU is an independently functioning dwelling and requires compliance with the 2018 IRC and City of Tucson building ordinances. A dwelling unit (includes a kitchen) requires collection of development impact fee when the building permit is processed, City of Tucson Ordinance #11203. Each dwelling unit building requires a separate Pima County assigned street address, R319. Notate each dwelling address on the site plan. SITE PLAN: 1. Show the location and size of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1. Identify the utility lines requiring upgrade or replacement. FLOOR PLANS: 1. Show compliance with R310 providing egress from the basement with minimum net clear opening area of 5.7 SQ FT. STRUCTURAL PLANS: 1. Provide a complete cross-section detail from foundation to roof assembly for the exterior wall including the basement, R106.1.1. Provide an engineer’s calculation, design and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1. 2. Provide a cross-section detail for the spiral stair foundation including reinforcement, R106.1.1. SECTIONS - DETAILS: 1. Notate and size all roofing drains and scuppers for flat roofed areas, R903.4. A 4” minimum width is required for the area served at a 3 in/hr rainfall rate, UPC 1101.11.2.1 & Table 11-1, IPC 1107.3. PLUMBING PLANS: 1. Provide a complete plumbing plan for proposed areas in the main dwelling, 2018 IRC. 2. Show an existing or upgraded 1” line to the dwelling. Minimum size for a pipe supplying two bathrooms within the building is 1”, P2903.7. MECHANICAL PLANS: 1. Provide a complete mechanical plan for proposed areas in the main dwelling, 2018 IRC. 2. Provide an equipment specification list including the (fans, furnace and AC) size or capacity, M1302.1. Include a Manual J report, M1401.3, M1601.1. ELECTRICAL PLANS: 1. Provide an electrical plan for the loft area in the main dwelling, 2018 IRC. 2. Smoke alarms are required in each separate sleeping area, R314.3. Show a smoke alarm in each bedroom and outside the doorway in the immediate vicinity. 3. Show the dishwasher/disposal with 20A breaker, E3703.7. 4. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. 5. Show Bathroom receptacles with a separate 20 AMP dedicated circuit, E3703.4 and E3901.6. OUTDOOR LIGHTING CODE 1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace, in a utility or laundry room, N1101.14. Add notation to plans. If you have any questions, please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 08/25/2023 | Site Engineering | REQUIRES RESUBMIT | 1. Clarify setback of wall from property line, if less than 9 feet, a floodplain use permit will be required, and floodventing bricks will need to be added to the wall every 4-5 ft. 2. Any wall over 8' will need a separate wall permit for structural review Scott Haseman scott.haseman@tucsonaz.gov |
||
| 09/05/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0823-07454 940 North Longfellow Avenue – R-1 Residential addition and perimeter wall (1st Review) TRANSMITTAL DATE: September 5, 2023 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. The following comments may be relative to an application for a Design Development Option (DDO) (UDC 3.11.1). 1. The proposed ADU and garage require a separate address and shall be reviewed under a separate permit number. Remove all construction drawings related to the ADU and garage in the resubmittal. The following comments only relate to the proposed addition and perimeter wall. Be aware that the proposed lot line adjustment requires a separate land division application. 2. Include the vehicular use area, whether improved or unimproved, in the lot coverage calculation (UDC 6.4.3.B.3.b). 3. Provide dimensions on Sheet C-1 from the centerline of Longfellow Avenue to the front street lot line, and from the face of curb to the front street lot line. Per Paving Plan I-66-004, the distance between the centerline of Longfellow Avenue and the front street lot line is 25 feet, and the distance between the face of curb and the front street lot line in eight feet. 4. The Pima County Assessor’s Office effective date of construction of this property is 1947. The actual construction date may be earlier. The existing front porch is proposed to be demolished. Buildings, portions of buildings, or structures that are 50 years of age or older must be architecturally documented prior to demolition. Documentation shall be reviewed and approved by the City Historic Preservation Office prior to zoning approval of this building permit. The demolition documentation information may be found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/planning-amp-zoning/historic_demolition_application_form.pdf. Submit the completed documentation as “Additional/Supporting Documentation” under permit number TC-RES-0823-07454. 5. Per UDC 6.6.2.I, the maximum height of a wall or fence within a perimeter yard is six feet. The proposed height is 8’-2” based on the elevation drawings, and the proposed height in keynote 14 on Sheet C-1 is 8’-0”. Clarify the height discrepancy. A Design Development Option (DDO) can be used to allow the proposed perimeter wall to exceed this height requirement as long as the highest points of the crenellations and pilasters are eight feet in height. A Board of Adjustment variance is required to be granted if the highest points of the crenellations and pilasters exceed eight feet in height. The DDO application and its requirements may be found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/planning-amp-zoning/2019_ddo_for_setback_and_height_udc.pdf. Contact Georgia.Pennington@tucsonaz.gov should you have questions about the DDO process. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 08/25/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | Permit is only for SFR addition. Applicant will need to submit for a separate for ADU/garage. |