Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0823-07428
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/25/2023 | Site Engineering | NOT REQUIRED | |||
| 09/11/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/11/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0823-07428 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. SITE PLAN: Provide a site plan showing the location of all buildings and utilities, R106.1.1. Show the location of all utility lines to the proposed building(s) along with required service alterations. SECTIONS - DETAILS: 1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF. PLUMBING PLANS: 1. Clarify the water heater notation, R301.1. MECHANICAL PLANS: 1. Provide the HVAC system size, M1401.3, M1601.1. Show the HVAC size in accordance with building loads calculated in accordance with Manual J. ELECTRICAL PLANS: 1. Show the sub panel location with a working space of 30” wide x 36” deep, E3405.2. 2. Show Bathroom and Kitchen receptacles with a separate 20 AMP dedicated circuits, E3703.2, E3703.4 and E3901.6. Update circuit labels for #3 and 11. OUTDOOR LIGHTING CODE Show the outdoor fixtures as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 09/06/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0823-07428 4522 East 8th Street – R-1 Addition (1st Review) TRANSMITTAL DATE: September 6, 2023 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. 1. Provide a site plan that meets the residential plot plan requirements found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf. At a minimum, the site plan shall: a. Indicate the scale of the plan (i.e., 1” = 20’); b. Include the square footage of the lot, the existing dwelling, the proposed addition, and of all accessory structures; c. Provide a lot coverage calculation (the area of the site occupied by buildings, storage areas, and vehicular use areas); d. Include a legal description of the property; and e. Show the setbacks from the proposed addition to the south and east lot lines. 2. Show all structures on the site plan. Two detached accessory structures in the front yard appear in aerial photography in 2022. Clarify whether these structures are to remain or not. A Board of Adjustment variance is required to be granted to allow these structures to remain detached in the front yard (UDC 6.6.3.C). These structures also do not meet the required front street perimeter yard setback of twenty feet (UDC 6.4.5.C.1.a). 3. Perimeter yard requirements are based on a measurement from the design grade elevation to the highest point of the exterior wall (UDC 6.4.5.B and Figure 6.4.5-A). Provide measurements from the design grade elevation to the highest point of the exterior walls to determine setback requirements. Per UDC Table 6.3-2.A, when a residential use is adjacent to a residential zone, the required setback is six feet or two-thirds the height of the exterior wall, whichever is greater, measured from the side or rear lot line. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 08/24/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |