Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-0823-07411
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/31/2024 | Site Engineering | NOT REQUIRED | |||
| 07/31/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/17/2024 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0823-07411 (417 S STRATFORD DR TUCSON, AZ 85716) 2nd Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). New Carport Review: General Notes: 1. The South side of the carport is shown as 1 foot from the property line. The carport requires a 1-hr fire rated wall assembly along this side of the carport, from ground to the underside of the roof sheathing. Or move the structure out of the 3 foot fire separation zone. You cannot have an open structure this close to the property line. You also cannot have the roof overhang on this side of the carport, R302.1 (City of Tucson Amended): https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2018_-_irc_amendments.pdf 2. Exterior structures with a fire separation distance less than 3-foot to the line of separation from the property line, requires not less than one-hour fire-resistive construction. Show compliance with R302.1 (City of Tucson Amended) by providing a section detail of materials prescribed in IBC Table 721.1(2), Items 15-1.1 to 16-1.3. 3. Deferred Submittal: Provide manufacturer’s calculations and data for pre-engineered trusses dated and wet-sealed by an engineer who is registered in Arizona, or notate the requirement for deferred submittal, R106.1. Show truss calculations with cross-reference to the plans, R802.10.2. Structural Notes: 4. Provide consistent information on the plans. Sheet 2 of 4, Framing Plan, shows Beam sized at 4”x12” and one at 4”x10”. Sheet 3 of 4, #1 section Detail, shows a Beam sized at 6”x10”. Electrical Notes: 5. Show the conductor type and conduit size/type. Use type thwn or thwn-2 conductors in ¾” conduits listed in Table E3801.2 and Table E3801.4. See E3802 and E3803 for above ground and underground electrical requirements. If the electrical is to be done under a separate permit, remove the electrical from the plans. Outdoor Lighting Code Notes: 6. Show the proposed light fixture, located with 25 feet from the property line, as Full Cutoff, OLC 401.3.3. Make this notation on the plans. (This is noted on response letter, but needs to be noted on the plans as well). Attached Shed Review: General Notes: 7. The North side of the attached shed is shown on the property line. The carport requires a 1-hr fire rated wall assembly along this side of the shed, from ground to the underside of the roof sheathing, R302.1 (City of Tucson Amended): https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2018_-_irc_amendments.pdf 8. Exterior structures with a fire separation distance less than 3-foot to the line of separation from the property line, requires not less than one-hour fire-resistive construction. Show compliance with R302.1 (City of Tucson Amended) by providing a section detail of materials prescribed in IBC Table 721.1(2), Items 15-1.1 to 16-1.3. 9. Please provide a wall detail, from foundation to roof sheathing, for code compliance verification. Structural Review: 10. 4”x4” beam is undersized for the given span and tributary area. Provide a beam sized to support the design loads of 20lbs psf live load and 10lbs psf dead load. 11. The 2x4 rafters @24”OC are undersized for the given rafter span. Provide rafters sized/spaced per R802.4.1 and Table R802.4.1(1). 12. On sheet 4 of 4, Detail 3, Porch Section Detail, provide a detail of the bearing post’s connection to the bottom plate and the bottom plate to the masonry wall. Show this detail from the foundation to the beam. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 07/08/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0823-07411 417 South Stratford Drive – R-1 Detached carport (2nd Review) TRANSMITTAL DATE: July 8, 2024 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. The following comments may be relative to an application for a Design Development Option (DDO) (UDC 3.11.1). 1. Zoning acknowledges signed neighbor's setback waivers were obtained for the detached accessory structure in the rear yard. Ensure only the waivers signed by the owners of 409 South Stratford Drive, 2610 East Malvern Street, and 2650 East Arroyo Chico are pasted directly onto the site plan. All other waivers received are not applicable to this structure. 2. This comment has not yet been addressed. Remove the existing 247 sq. ft. "back porch" and 100 sq. ft. "porch" from the lot coverage calculation. Roofed areas, open on at least one side, which provide shelter to exterior areas, provided they are not used for utilities, maintenance, laundry, storage, or motor vehicle parking, are excluded from the lot coverage calculation (UDC 6.4.3.C.1.a). 3. This comment has not yet been addressed. Perimeter yard requirements are based on a measurement from the design grade elevation to the highest point of the exterior wall (UDC 6.4.5.B and Figure 6.4.5-A). As measurements from design grade were not provided, an additional six inches have been added. Based on a wall height of 9’-6”, the required setback from the south property line to the posts of the carport is 6’-4”; the proposed setback is 1’-0”. Zoning acknowledges a neighbor's setback waiver was provided to reduce the required side perimeter yard for the carport. However, the waiver was not signed by the owner of 425 South Stratford Drive listed on the Pima County Assessor's Office. Ensure this waiver is also pasted directly onto the site plan. A DDO will be required to reduce the side perimeter yard setback if this waiver cannot be obtained. 4. Remove the "this project" reference for the 100 sq. ft. porch, as this porch does not require review. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 07/29/2024 | Zoning Modifications - DDO | REQUIRES RESUBMIT | DATE: 7/29/24 FROM: GEORGIA PENNINGTON, PLANNER COMMENTS: 1. Address Site Zoning comments. If you have questions about this transmittal, please contact me at georgia.pennington@tucsonaz.gov |
||
| 06/25/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |