Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0823-07397
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/24/2023 | Site Engineering | NOT REQUIRED | |||
| 09/01/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/29/2023 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0823-07397 (1992 W CALLE CAMPANA DE PLATA TUCSON, AZ 85745) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). General Notes: 1. Sheet 2, Wall Section Notes, Note 9, add “Anchors within 12” of each sill plate end”, R403.1.6. Mechanical Plans: 2. Provide demand calculations for the New AC, in accordance with Manual J/S/D standards, M1401.3, M1601.1. Systems shall be sized in accordance with Manual S based on building loads calculated in accordance with Manual J and duct systems sized in accordance with Manual D. 3. Moving the gas fired water heater requires a gas plan with the submission of a gas pipeline template (or equivalent), G2401.1, R301.1: https://www.tucsonaz.gov/files/pdsd/permits/Gas_Piping_Template.pdf See also: https://www.tucsonaz.gov/files/pdsd/permits/GAS_HANDOUT_2018_IRC_2019.2.4.pdf https://www.tucsonaz.gov/files/pdsd/permits/Sample_Gas_Template_0.pdf Provide a gas piping plan showing the connection from the meter to the WH. Include pipe size, type and length. Provide WH gas demands. G2413.4.1. Is the Clothes dryer gas fired as well? If so, include it in the gas plans. 4. Show dryer vent size and location for venting to exterior, M1501. 5. Show that the maximum length of dryer vent does not exceed 35’ with consideration of bend reductions, M1502.4. Electrical Plans: 6. Show locations of each smoke alarm, R314. Notate that all smoke alarms must be interconnected with a power source from the building wiring and be equipped with battery backup. When ceiling finish materials are removed in existing construction, existing bedrooms shall be brought into compliance. When ceiling finish materials are not removed, existing bedrooms may be equipped with battery operated smoke alarms, R314.2. 7. Smoke alarms are required outside each separate sleeping area, R314.3.2. Show a smoke alarm in each bedroom and outside the doorway in the immediate vicinity. 8. Show the location of a carbon monoxide detector outside of bedroom doors, when the dwelling includes an attached garage or gas appliance, R315. 9. Notate light fixture placement in clothes closets in compliance with E4003.12. 10. Clarify the Dryer’s power hookup circuit. Plumbing plans: 11. Notate and specify all piping materials and sizes, P2608. Include existing building sewer pipe. Show all new plumbing work on the plumbing plan. 12. Provide a water hammer arrester for quick-closing valves serving the clothes and dish washers, P2903.5. 13. Show plumbing vents (VTR) within acceptable distances from traps for the clothes washer, P3105.1. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 09/01/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0823-07397 1992 West Calle Campana – R-1 Addition (1st Review) TRANSMITTAL DATE: September 1, 2023 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. The site is in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in the R-1 zone, subject to use-specific standards 4.9.7.B.5-.9. 1. Remove the proposed porch from the lot coverage calculation as roofed areas, open on at least one side, which provide shelter to exterior areas, provided they are not used for utilities, maintenance, laundry, storage, or motor vehicle parking, are exempt from the lot coverage calculation (UDC 6.4.3.C.1.a). Additionally, include the vehicular use area, whether improved or unimproved, within the lot coverage calculation (UDC 6.4.3.B.3.b). 2. The Aldea Vista subdivision plat (https://maps-and-records.tucsonaz.gov/subdivisions/details/MP-14072&) indicates that the dimensions of Lot 26 are 79.5 feet by 102 feet. Provide the correct lot dimensions are provided on the site plan to ensure setbacks are depicted accurately. 3. Show all structures on the site plan. A detached accessory structure in the rear yard appears in aerial photography beginning in 2014. A zoning compliance review was not obtained for this structure. A previous Zoning Administrator’s determination states that a detached accessory structure that does not meet perimeter yard requirements may remain if the structure was constructed at least five years ago, is under 200 square feet, and is not connected to any utilities. 4. Perimeter yard setbacks are based on a measurement from the design grade elevation to the highest point of a building wall (UDC 6.4.5.B and Figure 6.4.5-A). Per UDC Table 6.3-2.A, when a residential use is adjacent to a residential zone, the required side and rear perimeter yard setbacks are six feet or 2/3 the height of the exterior building wall, whichever is greater. Provide measurements from the design grade elevation to the highest point of the exterior walls to verify and determine the setback requirements for the proposed addition and porch. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 08/23/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |