Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0823-07317
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/29/2023 | Site Zoning | APPROVED | |||
| 09/07/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/07/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0823-07317 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. PLANS: 1. Show the door from a garage to dwelling with a 20-minute fire rating (or 1-3/8” solid core) with self-closing and self-latching provision, R302.5.1. 2. Show a ½” gypsum board (garage side) on all walls common to the garage and house or other fire rated product in compliance with R302.6. 3. Remove any window openings at walls common to the garage and house and notate fill-in materials, R302. SECTIONS - DETAILS: 1 Show the minimum 12” x 12” continuous #4 rebar reinforced footing, R403.1. ELECTRICAL PLANS: 1. Show all garage receptacle outlets with GFCI protection, E3902.2. OUTDOOR LIGHTING CODE Show the proposed fixture as full cut off style or provide an Outdoor Lighting Calculation. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: Ken Van Karsen (520) 791-5550 City of Tucson Residential Plan Review |
||
| 08/22/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 08/22/2023 | Site Engineering | REVIEW COMPLETED |