Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0823-07309
Parcel: 12512069A

Address:
3462 E 2ND ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0823-07309
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/22/2023 Site Zoning APPROVED
08/22/2023 Site Engineering NOT REQUIRED
08/24/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
08/24/2023 Residential Building REQUIRES RESUBMIT 1. Provide plans showing the correct address for each Single Family or Duplex dwelling address. (same plan set) 2. Show existing or proposed 1-hour rated wall between units, R302.4. 3. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. 4. Show new or extended interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3902.16 & 17.
08/21/2023 PDSD Application Completeness REVIEW COMPLETED