Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0823-07237
Parcel: 113101420

Address:
1628 E COPPER ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0823-07237
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/26/2023 Site Engineering NOT REQUIRED
09/11/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/11/2023 Residential Building REQUIRES RESUBMIT 1. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. GFCI protected, E3902.6.
2. Show Bathroom receptacles with a separate 20 AMP dedicated circuit, E3703.4 and E3901.6.
3. Show one 20 AMP branch circuit in the (clothes washer) laundry area; this circuit may not serve other locations, E3703.3 and 3901.8.
4. Show one 20 AMP branch circuit for the dishwasher/disposal; this circuit may not serve other locations, E3703.8 City of Tucson Amended.
5. Show new or extended interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3902.16 & 17.
09/06/2023 Site Zoning REQUIRES RESUBMIT FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: TC-RES-0823-07237
1628 E COPPER ST Zoning R-2

TRANSMITTAL DATE:‎September 6, 2023


COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1.COMMENT: Provide a Residential Plot Plan that meets the requirements found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf
This shall in include:
a. Property line distances Provided in the link below is the subdivision plat map,
https://maps-and-records.tucsonaz.gov/subdivisions/details/MP-04017&


2.COMMENT: Draw dimension and label the height of the new structure measured from design grade to top of wall.

3.COMMENT: Provide a dimension from the proposed structure to the property line. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).

If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
08/25/2023 PDSD Application Completeness Express REVIEW COMPLETED