Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-0823-07237
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/26/2023 | Site Engineering | NOT REQUIRED | |||
| 09/11/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/11/2023 | Residential Building | REQUIRES RESUBMIT | 1. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. GFCI protected, E3902.6. 2. Show Bathroom receptacles with a separate 20 AMP dedicated circuit, E3703.4 and E3901.6. 3. Show one 20 AMP branch circuit in the (clothes washer) laundry area; this circuit may not serve other locations, E3703.3 and 3901.8. 4. Show one 20 AMP branch circuit for the dishwasher/disposal; this circuit may not serve other locations, E3703.8 City of Tucson Amended. 5. Show new or extended interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3902.16 & 17. |
||
| 09/06/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-RES-0823-07237 1628 E COPPER ST Zoning R-2 TRANSMITTAL DATE:September 6, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Provide a Residential Plot Plan that meets the requirements found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf This shall in include: a. Property line distances Provided in the link below is the subdivision plat map, https://maps-and-records.tucsonaz.gov/subdivisions/details/MP-04017& 2.COMMENT: Draw dimension and label the height of the new structure measured from design grade to top of wall. 3.COMMENT: Provide a dimension from the proposed structure to the property line. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 08/25/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |