Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-0823-07229
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/10/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/10/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-0823-07229 (4205 S MANNING LN TUCSON, AZ 85714) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. Clarify the longest developed length, The length is measured from the meter to the furthest attached appliance for all sizing,G2413.4.1. The measurements on the plans, to the water heater, add up to 47’, not 35’. 2. Clarify the location of the gas line being fixed. 3. Provide the size of the main line pipe coming out of the meter, G2413.3, G2413.4.1. This portion of the gas pipe should be sized a minimum of 1”, Table G2413.4(1) (Metallic Pipe). (200,000 btu, 50’ length). |
||
| 08/10/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |