Permit Number: TC-RES-0823-07201
Parcel: 134160870

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.3

Permit Number - TC-RES-0823-07201
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/16/2024 Residential Building APPROVED
04/29/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/29/2024 Site Zoning REQUIRES RESUBMIT FROM: Nathan Herrera
PDSD Zoning Review Section

PROJECT: TC-RES-0823-07201
7321 E Beverly Dr. Tucson, AZ. 85710
Parcel: 134-16-0870
Zoning: R-1
Project Scope: Detached Accessory Structures

TRANSMITTAL DATE:‎ April 29, 2024

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5-9.

1. COMMENT: Per UDC 6.3-2.A, the required setback in the R-1 zone is the greater of 6 feet or 2/3 the height of the proposed building wall.
Structure A has a height of 9 feet 1 inch, the required setback is 6 feet 1 inch. The proposed setback to the northern property line is 1 foot 4 inches. The proposed setback to the western property line is 1 foot.
Structure B has a height of 7 feet 8 inches, the required setback is 6 feet. The proposed setback is 1 feet 4 inches to the northern property line.
Structure C has a height of 9 feet 1 inch, the required setback is 6 feet 1 inch. The proposed setback is 2 feet to the northern property line.
Structure D has a height of 8 feet 7 inches, the required setback is 6 feet. The proposed setback is 2 feet to the northern property line, and 3 feet 6 inches to the eastern property line.
Structure G shown on the site plan has a height of 8 feet 1 inch, the required setback is 6 feet. The proposed setback is 3 feet 6 inches to the eastern property line.
Structure E has a height of 9 feet 4 inches, the required setback is 6 feet 3 inches. The proposed setback is 3 feet 6 inches to the eastern property line.

2. COMMENT: Per UDC Article 6.4.5.C.1.a, For single-family and duplex development, the minimum required front street perimeter yard is 20 feet measured from the street property line.
Per UDC Article 6.4.5.D.3, Shade structures or carports may project up to ten feet into required street perimeter yards.
Structure G has a required front yard setback of 10 feet. The proposed setback is 2 feet 4 inches from the street property line.


3. COMMENT: A Design Development Option (DDO) must be applied for and approved in order to reduce the setbacks as proposed before this permit can be approved by Zoning.
For more information about the DDO process contact Wyatt Berger at wyatt.berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: revised residential building permit along with a detailed response letter, which states how all Zoning Review Section comments were addressed. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf

If you have any questions about this transmittal, please contact Nathan Herrera at Nathan.Herrera@TucsonAZ.gov .
04/17/2024 Zoning Modifications - DDO REQUIRES RESUBMIT The DDO application has been accepted for processing. Please allow 4-6 weeks for this process. If the application is approved, please include in your required comment response letter the following information: DDO case number, the request, and condition(s) of approval. If you have questions, please email Mark.Castro@tucsonaz.gov
03/28/2024 PDSD Application Completeness Express REVIEW COMPLETED