Permit Number: TC-RES-0823-07156
Parcel: 134211570

Address:
7053 E HAYNE PL

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0823-07156
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/25/2023 Site Engineering NOT REQUIRED
09/06/2023 Site Zoning NOT REQUIRED
09/11/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
09/11/2023 Residential Building REQUIRES RESUBMIT TC-RES-0823-07156
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes.

Structures built without a permit may require alteration for building code compliance.

Provide a clear and concise construction plan set. Sample drawings are shown as an example: https://www.tucsonaz.gov/pdsd/residential-permits

SITE PLAN:

1. Indicate the location and size of utility meters and lines supporting the alterations, R106.1.1. Show the utility lines requiring upgrade or replacement.
2. The roof structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by removing the roof placed within 3 feet to the property line or provide a complete wall barrier with not less than one-hour fire-resistive construction in compliance with IBC Table 721.1(2) or provide a Pima County processed utility easement preventing construction within 3 feet of the structure on the neighboring property.

STRUCTURAL PLANS:

1. Show the location of each support footing, R106.1.1.
2. Provide a Roof Framing Plan showing the location and size of beams, headers, and rafters for supporting live and dead structural loads, R804.

SECTIONS - DETAILS:

1 Show reinforced footing dimensions required for post/beam construction, R403.1.1.
2 Show a complete cross-section detail with post to foundation fasteners, R407.3 & R507.4.1.
3 Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended.

ELECTRICAL PLANS:

1. Show any electrical alterations.

If you have any questions, please contact:
Ken Van Karsen
(520) 791-5550
City of Tucson Residential Plan Review