Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-0823-07143
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/25/2023 | Site Engineering | NOT REQUIRED | |||
| 09/01/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/29/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0823-07143 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. SITE PLAN: Provide a site plan showing the location of all buildings and utilities, R106.1.1. Show the location of all utility lines to the proposed building along with required service alterations. The overhead electrical line may not pass over (within 8 feet) the roof. PLANS: Provide a slope and scupper location of the “flat roof” on sheet 5, R310. STRUCTURAL PLANS: 1. Provide a complete structural (roof framing) plan including headers showing compliance with the IRC, R301.1. SECTIONS - DETAILS: 1. Provide a structure wall section showing existing and proposed features including exterior sheathing, R106.1. PLUMBING PLANS: 1. Provide complete plumbing plans showing any changes with 2018 IRC compliance, R301.1. 2. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate yard pipe for supporting the existing and proposed dwelling units. 3. Show an individual accessible water supply shut off and water heater for the proposed dwelling building, P2903.9.1. MECHANICAL PLANS: 1. Show heating facilities in all habitable rooms, R303.9. ELECTRICAL PLANS: 1. TEP may require the service panel for the property at the closest building to the service transformer. A service line change or a new meter location must be coordinated with TEP for approval. Show an underground feeder from a metered service panel to the more distant building. 2. Provide a Riser Diagram showing a sub panel and feeder size for proposed dwelling unit, NEC 225.30, E3403, Table E3704.2(1). 3. Provide a panel schedule showing panel size, circuit numbers, ampacity, wire size and general description, E3404.13 & E3706.2 Provide proposed wiring details showing code compliant device locations and circuit sizes. 4. Show the bathroom with a dedicated 20 AMP circuit. 5. Show at least one wall-switch-controlled lighting outlet providing illumination on the exterior side of each egress door having grade level access R3903.3. 6. Notate interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors with combination type arc-fault circuit interrupters, E3902.16. OUTDOOR LIGHTING CODE Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 09/01/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0823-07143 2517 East Alta Vista Street – R-2 ADU (1st Review) TRANSMITTAL DATE: September 1, 2023 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. The site is in the R-2 zone (UDC 4.7.9). An accessory dwelling unit (ADU) is a permitted use in the R-2 zone, subject to use-specific standards 4.9.7.B.6, .8, and .9, and 6.6.3. 1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf. At a minimum, include the following information on the site plan: a. Include the legal description GRANT ROAD PARK NO 2 W60’ OF E180’ OF L 7 BLK 8; b. Ensure the lot coverage calculation includes the proposed ADU; c. Show the setbacks measured from the north, east, and west lot lines to the proposed ADU; d. Indicate the zoning of the property and of surrounding properties; and e. Ensure that the dimensions of the lot are 100 feet by 60 feet as depicted on the subdivision plat. 2. Indicate the location of the motor vehicle parking space required for the proposed ADU. The parking requirement may be satisfied with available on-street parking or waived if the site is within ¼ mile walking distance of a transit stop or an enhanced bike route as listed in the Bike Boulevard Master Plan (UDC 6.6.3.B.2). 3. Provide a general note indicating that the ADU will be developed with a high albedo level (>60 SRI) or other cool roof technology per the ICC Green Construction Code (UDC 6.6.3.B.3). 4. On sites where the existing residence is one story, ADUs shall not exceed 12 feet in height. Building height is the vertical distance measured from the design grade elevation to the highest point of a flat roof; to the deck line of a mansard roof; or to the middle (between the eave and ridge) of the highest gable of a pitched or hipped roof (UDC 6.6.3.B.4). Demonstrate on the elevations or section drawings that the height of the ADU does not exceed 12 feet in height. 5. Perimeter yard requirements are based on a measurement from the design grade elevation to the highest point of the exterior wall (UDC 6.4.5.B and Figure 6.4.5-A). Per UDC 6.3.2-A, when a residential use is adjacent to a residential zone, the required setbacks are six feet or 2/3 the height of the exterior wall, whichever is greater, measured from the proposed south, east, and west lot lines. Additionally, when a residential use is adjacent to a non-residential zone, the required setbacks are ten feet or ¾ the height of the exterior wall, whichever is greater, measured from the north lot line. Provide measurements from the design grade elevation to the highest point of all exterior walls on the elevations to verify proposed setback requirements. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 08/25/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |