Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - TC-RES-0823-07143
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/01/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/01/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0823-07143 R1 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. SITE PLAN: Provide a site plan showing the location of all buildings and utilities, R106.1.1. Show the location of all utility lines to the proposed building along with required service alterations. The overhead electrical line may not pass over (within 8 feet) the roof. STRUCTURAL PLANS: 1. Provide consistent purlin sizes, R301.1. Section 1 sheet 4 shows 4x8 although Ortho View 1 and sheet 5 shows 4x10. PLUMBING PLANS: 1. Provide complete plumbing plans showing vent sizes with 2018 IRC compliance, P3113. 2. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate yard pipe size for supporting the existing and proposed dwelling units. ELECTRICAL PLANS: 1. TEP may require the service panel for the property at the closest building to the service transformer. A service line change or a new meter location must be coordinated with TEP for approval. Show an underground feeder from a metered service panel to the more distant building. 2. Provide a Riser Diagram showing a sub panel and feeder size between dwelling units, NEC 225.30, E3403, Table E3704.2(1). 3. Provide a note stating interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors with combination type arc-fault circuit interrupters, E3902.16. If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 10/17/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0823-07143 2517 East Alta Vista Street – R-2 Casita (2nd Review) TRANSMITTAL DATE: October 17, 2023 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. The site is in the R-2 zone (UDC 4.7.9). An accessory dwelling unit (ADU) is a permitted use in the R-2 zone, subject to use-specific standards 4.9.7.B.6, .8, and .9, and 6.6.3. 1. The proposed construction is considered a sleeping quarters. Per UDC 6.6.3, a sleeping quarters may include bedrooms, bathrooms, and a sitting room. Conversely, an ADU may include a kitchen, bedrooms, bathrooms, and a sitting room. Per UDC 6.6.3.E, the total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure. Accessory structures less than 200 square feet gfa and accessory dwelling units are exempt from this requirement. A Board of Adjustment variance is required to be granted to allow the proposed sleeping quarters to exceed 50% of the gfa of the existing dwelling. The variance process may be avoided if full cooking facilities are proposed, or if the structure is attached to the existing dwelling. Per a previous Zoning Administrator's determination, the structures may be considered attached if a connection at least five-feet-wide supporting a live load of at least 20 feet is proposed. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 10/17/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |