Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0823-07090
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/17/2023 | Residential Building | NOT REQUIRED | |||
| 08/14/2023 | Site Landscape | NOT REQUIRED | |||
| 08/17/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/14/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-RES-0823-07090 5844 E. Farmridge Dr. - SH Site Fence (1st Review) TRANSMITTAL: August 14, 2023 Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9. 1. Clearly show the proposed location of for the fence on the survey. 2. Based on aerial photos there is a structure along the east property line that shows up some time after 2005 and is also shown on the survey. Zoning was not able to find approved permit or compliance reviews for this structure. It appears that this structure is less than 200 sq. ft. and does not require a permit but does require a zoning compliance review. This review can be completed along with the fence review. Provide the height of this structure along with a perimeter yard setback dimension to the east property line. As this structure does not appear to meet the minimum setback to the east property line, 20’-0” (UDC Table 6.3-1.A) a neighbors setback waive is required. Per UDC Article 6.6.2.D An accessory structure that exceeds the allowable height of a wall within a perimeter yard and is detached from a principal structure shall comply with the perimeter yard width standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s): My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ 3. Per the Wilmot Farms final plat General Note 13 the maximum impervious surface 7%. Impervious surface includes all structures, & any paved areas. Provide a calculation that clearly demonstrates that the 7% is not exceeded. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov |
||
| 08/11/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 08/14/2023 | Site Engineering | REVIEW COMPLETED |