| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/28/2023 | Fire New Construction | NOT REQUIRED | |||
| 08/26/2023 | Site Engineering | NOT REQUIRED | |||
| 09/14/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/12/2023 | Residential Building | REQUIRES RESUBMIT | Show garage opening narrow panels with fastening details using a prescriptive 2018 IRC method at Figure R602.10.6.2, R602.10.6.3 or R602.10.6.4 or provide an engineer’s sealed plan set for a performance design when minimum sizes are not 2018 IRC compliant, R301.1. | ||
| 09/14/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Iman Monshizadeh PDSD Zoning Review Section PROJECT: TC-RES-0823-07047 / Garage addition Plot Plan Review (1st Review) 620 N Contzen Av / R-3 TRANSMITTAL DATE: 09/14/2023 COMMENT: This site is located in an R-3 zone. The minimum setback to the side and rear yards are 6’ or 2/3 * Height (whichever is greater). A Neighbor waiver will be required from both properties to the south and the east. Provide this statement signed by the adjacent property owners on the next submittal.. “My Name is ______________ and I am the owner of the property located at ____________. I have reviewed the site plan and I have no objections to structure being located or constructed ______ feet from the property line as depicted on the site plan Signature:__________________ Date:_______________” If a neighbor waiver cannot be acquired then the structure must meet setbacks or go through a Design Development Option to have its setbacks reduced. Information on the Design Development Option can be found here: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/2019_ddo_for_setback_and_height_udc.pdf COMMENT: Show all existing structures on the site plan. Aerials show 2 unpermitted structures and a shade sail on the site in 2008. Provide setback dimensions for the structures and show them on the site plan on the next submittal. If structures no longer exist or are to be removed, create a note on the plans stating it as so. COMMENT: provide a lot coverage calculation on the next submittal. An example of a lot coverage calculation can be found here: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov |
||
| 08/28/2023 | NPPO | REVIEW COMPLETED | |||
| 08/26/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |