Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - TC-RES-0823-07028
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/04/2023 | Historic | APPROVED | |||
| 10/17/2023 | Site Zoning | APPROVED | |||
| 10/17/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/16/2023 | Residential Building | REQUIRES RESUBMIT | 1. Show compliance with R310 providing egress from bedrooms with minimum net clear dimension of 24” height. This is provided with 3046 SH windows. 2. Show the location of a minimum 22” x 30” attic access, R807.1. 3. Clarify the roof insulation placement and ventilation requirement, R806. Remove the eave vents when providing an unvented roof design, detail #1 sheet 9. |
||
| 09/26/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |