| 08/14/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/14/2026 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov Please resubmit addressing the following comments: 1) Provide clarification regarding HVAC equipment sizing. The submitted Manual J identifies 1,730 ft² of conditioned floor area, while the dwelling is identified as 2,364 ft². The Manual J areas of 892 ft² and 838 ft² total 1,730 ft². Identify the remaining 634 ft² and clarify whether this area is conditioned or unconditioned. For equipment replacement, provide documentation supporting the conditioned floor area used in the Manual J calculation. 2) The proposed 3-ton and 4-ton systems shall be demonstrated to comply with 2024 IRC M1401.3 and 2024 IECC R403.7. Provide the Manual J cooling loads for each zone and corresponding Manual S equipment-selection calculations. Provide manufacturer/extended performance data identifying the sensible and total cooling capacities of the proposed equipment at the applicable design conditions. Revise the equipment sizing if the submitted Manual J/Manual S calculations do not support the proposed capacities. |
||