Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0726-04131
Parcel: 136233400

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR v.2

Permit Number - TC-RES-0726-04131
Review Name: RESIDENTIAL SOLAR v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/07/2026 Residential Zoning APPROVED
08/12/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/12/2026 Light Residential Building Review (OIP) - Standard REQUIRES RESUBMIT If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov
Please resubmit addressing the following comments:
1) The array calculations are not consistent with the proposed complete PV system. Provide lag-bolt connection embedment calculations demonstrating that the attachment and connection design for each array can adequately support the applicable wind loads. Alternatively, provide an engineer-prepared and sealed structural design/calculation package demonstrating compliance with the applicable design requirements. R301.1, R329.4.
2) A Surge Protection Device (SPD) or SPD model number must be identified on the plans for all service panel replacements supplying 100% of the dwelling. This requirement can be satisfied by providing the manufacturer’s specifications or model number for the SPD to verify that it is UL listed and code compliant E606.5 NEC 230.67
08/04/2026 PDSD Application Completeness Express REVIEW COMPLETED