Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0726-04041
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/28/2026 | Residential Engineering | NOT REQUIRED | |||
| 08/03/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/27/2026 | Addressing Validation | REQUIRES RESUBMIT | If you have questions regarding this review, please contact PDSD-Permits@tucsonaz.gov. Please include full property address on site plan and resubmit after other reviews are complete. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf |
||
| 07/28/2026 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0726-04041 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2024 International Residential Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2024 IRC with amendments and building ordinances for all dwellings. Place the reference code on the site plan and avoid placing code reference entries throughout the plans which become outdated. Clarify if the proposal is for an enclosed garage for additional dwelling space with a relocated kitchen or a new attached dwelling with an additional kitchen within the building. A living unit with kitchen is considered a dwelling ADU and will require an impact fee payment when the plans are approved. A permit requires the correct application type. Request the cancellation of this application for an addition/alteration permit and apply for a new dwelling permit if a second kitchen is proposed within the building. This addition/alteration application may continue if the kitchen is removed. Provide a complete construction plan set showing 2024 IRC compliance. Provide a separate response letter addressing each comment with location of change on the plans. GENERAL COMMENTS: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Building-Codes 1. A dwelling requires a fire barrier between units (duplex) without openings. Provide plans with independent utility connections for each dwelling unit. Or an addition requires the removal of the kitchen. Update the plans showing a wet bar without major appliances. 2. A new dwelling requires compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc. SITE PLAN: 1. Show the utility meters and lines from the utility source to the building, R106.1.1. Identify the utility lines requiring upgrade or replacement. 2. Show building square footage sizes from exterior foundations rather than interior surfaces for the proposed alteration. 3. Each dwelling building requires a street address and a separate permit, R319. Show Pima County assigned unit numbers at each dwelling on the site plan PLANS: 1. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1. Include all threshold conditions for a route from the exterior into the living space. 2. Individual dwelling units require separation with a 1-hour fire-resistance rated assembly without openings, R302.3. Provide a detail or notation showing compliance with 703.3 of the 2024 IBC. 3. Provide a complete floor plan with appropriate entrance door and egress window sizes, R318.2 &, R319.2. SECTIONS - DETAILS: 1. Show one-hour fire-resistive framed construction separating dwellings in compliance with IBC Table 721.1(2). 2. Provide a wall section detail with reinforced foundations for anchoring exterior framed walls with pressure treated sills including ½” anchor bolts with 7” embedment, R403.1.6. 3. Show exterior wood siding, sheathing, water-resistive barrier and wall framing with a 6” clearance above the ground (R317.1 item 5). The weep screed may extend with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1. 4. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. MECHANICAL PLANS: 1. Show the HVAC system size for the building demand in accordance with M1401.3, M1601.1. 2. Provide demand calculations in accordance with Manual J standards, M1401.3, M1601.1. 3. Identify the device model number providing an adjustable setting and note the minimum continuous or intermittent setting for providing whole-house mechanical ventilation, R303.4; N1103.6 & M1505.4. PLUMBING PLANS: 1. The Tucson Water Department limits flow rates for the water meter size in compliance with P2903.7. Show an appropriate water meter size for the additional demand. Show an appropriate yard pipe size with connection between the existing dwelling and the meter. 2. Show an individual accessible water supply shut off and water heater for the proposed dwelling unit, P2903.9.1. 3. Show the water heater rating/capacity for consistence with the electrical circuit size, R106.1.1. ELECTRICAL PLANS: 1. Show a separate distribution panel for the proposed dwelling, NEC 225.30 and E3403. A service line change or a new meter location must be coordinated with TEP for approval. 2. Provide a Riser Diagram showing a service disconnect for both the primary and ADU dwelling, E3403. Show the ADU feeder size and appropriate breaker requirement, E3602.1 & E3603.1. Show a minimum service conductor rating of #3 copper 75 degree C for the 100 AMP feeder, E3602.1 & E3603.1. 3. Show a surge-protective device (SPD) as an integral part of or placed immediately adjacent to the service equipment, E3606.5. 4. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3 5. Interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.20. Add notation to plans. 6. Provide GFCI protection for appliance receptacle outlets, E3902.12. Include: 1. Drinking water coolers 2. High pressure spray washing machines 3. Sump pumps 4. Dishwashers 5. Electric ranges 6. Wall-mounted ovens 7. Counter-mounted cooking units 8. Clothes dryers 9. Microwave ovens 10. Provide GFCI protection for receptacle outlets and HVAC equipment, E3902.14. OUTDOOR LIGHTING CODE 1. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans. If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 08/03/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-RES-0726-04041 4002 S 13th Av., Tucson, AZ 85714 Addition and Remodel (1st Review) TRANSMITTAL DATE: 08/03/2026 This site is located within the R-2 Zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. Submit a Full site plan. Instructions for the Full site plan are found at this link: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Site-Plan-Examples . Google Street View imagery from 2025 suggests the carport will be enclosed, yet this is not discussed in the materials submitted. 2. As part of the site plan instructions in Comment 2, the site plan must contain the dimensioned full lot and street among other items that must also be provided. The lot appears to measure 55’ X 137’ as shown in the Pima County Assessor’s map, accessible here: https://www.asr.pima.gov/ParcelData/Map/Arm/MP07/07062_01.PDF 3. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov . |
||
| 07/27/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |