Permit Number: TC-RES-0726-04036
Parcel: 140398820

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0726-04036
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/07/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/27/2026 Residential Building REQUIRES RESUBMIT ACTIVITY NO. TC-RES-0726-04036
ADDRESS/PARCEL: (4801 E LOS REALES RD TUCSON, AZ 85756)
Submit your revised reports along with a response letter which states how all Building Review Section comments were addressed. The submitted documents were incomplete, and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. Should you have any questions about these comments, I can be reached at ian.gillaspie@tucsonaz.gov.
COMMENTS:
1. Specify the location of all utility lines, sewer, and service meters on the site plan, R106.1.1.
2. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc.
3. Plans submitted for a newly constructed one- or two-family dwelling after June 1, 2010, require gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. The ordinance revision now requires a gray drain line discharge from one fixture for a one-story dwelling. Additional gray fixture drains are optional. Show a second clothes washer standpipe plumbed to an exterior wall above grade when feasible, or a bathing fixture drain looped 3’ beyond an exterior wall below grade before connection to the building drain. Use the appropriate detail at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation Gray Water Illustrations.
4. Show compliance with the Electric Vehicle Supply Equipment Ordinance adopted by the City of Tucson Ordinance #11844 on 6/22/2021. Include a 40 ampere 240-volt dedicated branch circuit with a NEMA 14-50R receptacle for charging an electric vehicle at a proposed parking space.
5. Please specify the height of roof of living area R106.1.1.
6. Provide a wall section detail with reinforced foundations for anchoring framed walls that will be supporting the ceiling joists of the living area with pressure treated sills including ½” anchor bolts with 7” embedment, R403.1 & R403.1.6.
7. Please correct and resubmit.
08/07/2026 Residential Engineering REQUIRES RESUBMIT Permit: TC-RES-0726-04036
Project: Addition/Alteration
Location: 4801 E LOS REALES RD
Review Date: 8/7/2026

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter review time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. Provide a response letter addressing each comment with location of change on the plans. Submit the separate response letter and plan set files.
1. A site plan is required for review that shows the proposed location of the building in relation to the property, dimensions and locations of any existing easements and required setbacks. The requirements for a site plan may be found here: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Site-Plan-Examples.
2. E LOS REALES RD has a current designation as Arterial per MS&R 10-8-25 amended map. Sight visibility triangles (SVT) will need to be shown for current and future ROW for all entrances/exits to the site. TSM 10-01.5.0
3. The existing proposed ROW for E LOS REALES RD is 130ft. Please provide linework with label and dimensions on the site plan for the proposed ROW and location of the proposed building in relation to it.
4. Please review and address Zoning comments.

If you have any questions or concerns, please contact Joe Macaulay at: Joe.Macaulay@tucsonaz.gov
07/31/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston
Planner
PROJECT: TC-RES-0726-04036
4801 E Los Reales Rd., Tucson, AZ 85756
SFR (1st Review)

TRANSMITTAL DATE: 07/31/2026

This site is located in the R-3 zone (Unified Development Code (UDC) Article 4.7.12). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. Contact the Department of Transportation and Mobility (DTM) to inquire about a driveway permit and development fronting Los Reales Rd. DTMpermits@tucsonaz.gov This road is an arterial, is part of the Master Streets and Roads masterplan, and future development by the City may increase the width by at least 130’.

2. Show the driveway width on the site plan.

3. Show all utility lines on the site plan.

4. Add a landscape plan to the site plan. (Sheet A-1). There is no need to hire a landscape architect. Here is the link to the landscape requirements, which went into effect January 1, 2026:
https://middle-housing-cotgis.hub.arcgis.com/pages/Residential-Landscaping-Code

a. Required landscape includes the following: 1 tree per every 1,000 sf of new residential development, rounded up. Fifty percent (50%) of the required trees need to be located in the front yard setback- again, please contact DTM to see if any changes will be required to the lot.
b. Existing trees 4” in diameter may count towards this requirement if their root systems are protected during construction and the mature tree canopy will not be compromised by proposed structures.
c. Trees must planted no less than 10’ from foundations and 5’ from utility lines and sidewalks.
d. Refer to https://middle-housing-cotgis.hub.arcgis.com/pages/Residential-Landscaping-Code for instructions on requirements for depressed planning areas.
e. Groundcover, which could include shrubs, is also required and is to be placed in the front yard setback. To calculate required groundcover square footage, subtract the curb cut permitted by DTM from the lot’s width. Multiply this figure by 5.
f. Label the specific tree and plant species – botanical names are not required. (UDC section 7.6.8.A.3 lists species criteria). All plants and trees are to be low water/drought tolerant; please refer to the link above.
g. Specify the preferred watering method.

Please note that the shrubs/groundcover areas may overlap tree(s) located in the front yard as shown in the examples found at https://middle-housing-cotgis.hub.arcgis.com/pages/Residential-Landscaping-Code .

5. The City of Tucson Inclusive Home Design Ordinance requires all new dwellings — including ADUs, single-family residences, and duplexes — to provide an accessible route connecting the public street, sidewalk, or driveway to an accessible entrance of the home. This pathway must be shown, dimensioned, and labeled on the plans. What this means in plain terms: There needs to be a clearly defined, walkable path from where a person arrives (the street, sidewalk, or driveway) all the way to a usable door of the home — one that someone using a wheelchair or mobility aid could navigate without barriers. An exterior accessible route that shall conform to 2017 ICC A117.1 Sections 402 and 403 and City of Tucson Inclusive Home Design Ordinance.
Reference: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf
6. Action Items — Show the following on your plans:
a. Draw and label the path as "Accessible Route"
b. Provide a minimum clear width of 4 feet with a width call-out on the plans
c. Note the proposed running slope (must not exceed 5% / 1:20) and cross slope (must not exceed 2% / 1:50)
d. Identify the accessible entrance the route leads to
e. Acceptable Accessible Route compositions include:
i. Portland cement concrete (PCC)
ii. Broom Finished concrete
iii. Brick or unit pavers (Only if set on a stable cement base with no gaps exceeding ½”)
iv. Concrete pavers on concrete base (Same joint and evenness requirements as brick)
v. Flagstone: must be mortared – loose set does not qualify
vi. Any surfaces equivalent in smoothness, hardness, and durability
NOTICE: Decomposed granite (DG) is not permitted for required accessible routes, even if compacted

7. For the next submittal, provide the following:
a. Revised site plan
b. Revised construction plans.
c. Response letter explaining how all staff comments have been addressed.

8. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov .
07/24/2026 PDSD Application Completeness Express REVIEW COMPLETED