Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0726-04021
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/06/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/06/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit Activity Number: TC-RES-0726-04021 (1st Review) Project: Removal of 25 ft of back fence to place an 8.5 x 20 ft container Location: 5417 E 9TH ST Review Date: 8/6/2026 Reviewer: Marco Contreras – Engineering Associate - Site Engineering Reviewer Contact: Marco.contreras@tucsonaz.gov Related cases: Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed to ensure final approval from Site Engineering. To help speed up your resubmittal and facilitate shorter review timelines, please include a response letter along with your updated plans and any supporting calculations. In your response letter, address each comment individually and explain what changes were made and where they can be found in the plans. Please do not mark or highlight changes in the drawings at this stage — revision markups are only used after a permit has been issued. Submit your response letter and updated plan set as two separate files. Site Engineering Review Comments: 1. Provide all property line dimensions onto the plans. 2. Dimension the distance between the proposed shed and existing home. |
||
| 07/30/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Claire Leighou, Planner PROJECT: TC-RES-0726-04021 5417 E 9TH ST Shed and Partial Wall Demo (1st Review) TRANSMITTAL DATE: 7/30/26 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9. Comment 1: Please provide the following missing information on the site plan upon next submittal. Use the link below as a reference site plan from the City of Tucson: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/plan-samples/full-site-plan_feb2026.pdf Dimensions of the property, which are 104.89’ (west property edge) by 80.61’ (south property edge) per area subdivision map, found here (file 2): https://maps-and-records.tucsonaz.gov/subdivisions/details/1313 Include the property address and owner information on the site plan Lot coverage details. Please include a table or list of all enclosed structures and vehicular use areas (such as driveways/carports/garages) and total lot coverage percentage. Please draw, label, and dimension the setback distance between the west property line and the detached accessory structure, labeled Shed 2 on the site plan. Zoning staff was unable to find the permit for this structure. If it was previously permitted, please include documentation with the next submittal of this application. If it was not permitted, it may be included in this application. If the shed is closer than the required 5’ distance from the property line, a neighbor waiver may be used to allow the reduced setback. Per UDC Article 6.6.2.D, an accessory structure that exceeds the allowable height of a wall within a perimeter yard and is detached from a principal structure shall comply with the perimeter yard width standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s) (5409 E 9th St): My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ Comment 2: Based on aerial images of the site from this year, there appears to be a shipping container in the front yard of the property. Per UDC 6.6.3.C., detached accessory buildings are not permitted in the buildable area extending the full width of the lot between the principle building and the front street lot line, except for shade structures or carports under 400 square feet. Please draw, dimension, and label this structure on the site plan, and show either plans to remove it, or apply for a Board of Adjustment Variance to permit the structure. This structure may be placed in the backyard of the property as long as it follows the required 5’ setback distance from side and rear property lines. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov. Thank you! |
||
| 07/24/2026 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 07/28/2026 | Residential Building - Standard | REVIEW COMPLETED |