Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.2
Permit Number - TC-RES-0726-03958
Review Name: RESIDENTIAL ADD/ALT v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/20/2026 | Residential Engineering | NOT REQUIRED | |||
| 08/27/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/24/2026 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0726-03958 2nd PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are for the 2024 International Residential Code and 2024 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2024 code compliance. Provide a separate response letter addressing each comment with location of change on the plans. PLANS: 1. Remove all clouding and “delta 1” references, R106.1.1. Revision notes are used for any changed plans after the permit is issued. The response letter is used for recording updates during plan preparation. 2. Show the interior load bearing foundation on the Foundation Plan sheet A1.3 or provide an Arizona engineer’s calculation, design, and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1. 3. Update the Foundation Plan description on sheet M1.0 to Mechanical Plan. If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 08/27/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Erick Bieber Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0726-03958 – Residential Building 3018 E Kaibab Vista, Tucson, AZ 85713 Residential Addition/Alteration (2nd Review) TRANSMITTAL DATE: August 27th, 2026 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9 & .12. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. (Comment) Upon further review, a neighbor waiver is not sufficient to approve the proposed sleeping quarters conversion at 4.67’ from the east property line, as Zoning can locate a permit for the original garage. A Design Development Option (DDO) will be required. Please amend the DDO application form to include both the carport in the front as well as the proposed sleeping quarters. Both setback reductions can be considered on the same application. 2. (Comment) The DDO application was submitted incorrectly. Please submit the DDO application that includes both the carport and the sleeping quarters to the Zoning Modifications sub record that has been created. For instructions on how to apply for a sub-record, view the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov |
||
| 08/20/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |