Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.2
Permit Number - TC-RES-0726-03917
Review Name: RESIDENTIAL ADD/ALT v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/15/2026 | Residential Building - Standard | NOT REQUIRED | |||
| 09/15/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/14/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Claire Leighou, Planner PROJECT: TC-RES-0726-03917 5237 E 8TH ST Two Detached Carports (1st Review) TRANSMITTAL DATE: 9/14/26 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9. Comment 1: The provided setback distance between the east edge of the carport and the property line is 1.6’. The required setback distance for side yards in the R-1 zone is 5’. Per UDC Article 6.6.2.D, an accessory structure that is detached from a principal structure shall comply with the setback standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjacent property owner(s). To secure this neighbor setback waiver please attach the following statement on the site plan with a signature and date by the adjacent property owner(s) (5245 E 8th St). My name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _______________________Date: ___________________________ Comment 2: Please add the following information to the site plan: Label the adjacent street (E 8th Street) and the zoning designation (R-1 Residential) Provide lot coverage calculations. Include either a table or a list with the total square footage of the lot (8,925 square feet per Subdivision Plat Map dimensions 85’x105’), the square footage of the existing house, all driveways and vehicular use area(s), and the new carports. Include a total lot coverage percentage by combining all of the items listed and dividing by the overall lot square footage. Subdivision plat map may be found here: https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=09102 The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov. Thank you! |
||
| 09/10/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |