Permit Number: TC-RES-0726-03898
Parcel: 116011000

Review Status: Approved

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0726-03898
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
07/21/2026 Residential Building - Standard APPROVED NOTE: A 6' fire separation distance must be maintained between the existing SFR and new carport. Less than 6' separation requires 1 hour fire rating under any eave projections that extend into the fire separation distance as measured from the posts. If posts are within 6' of the existing structure then a 1 hour rated wall must be build on that side.
07/24/2026 Residential Zoning APPROVED
07/27/2026 Bldg Permits - Post Review Express REVIEW COMPLETED
07/20/2026 PDSD Application Completeness Express REVIEW COMPLETED