Permit Review Detail
Review Status: Approved
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0726-03898
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Approved
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/21/2026 | Residential Building - Standard | APPROVED | NOTE: A 6' fire separation distance must be maintained between the existing SFR and new carport. Less than 6' separation requires 1 hour fire rating under any eave projections that extend into the fire separation distance as measured from the posts. If posts are within 6' of the existing structure then a 1 hour rated wall must be build on that side. | ||
| 07/24/2026 | Residential Zoning | APPROVED | |||
| 07/27/2026 | Bldg Permits - Post Review Express | REVIEW COMPLETED | |||
| 07/20/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |