Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-0726-03818
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/15/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/15/2026 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov Please resubmit addressing the following comments: 1) The proposed sanitary drainage piping decreases in size from 3" to 2". Provide a drainage fixture unit (DFU) calculation demonstrating that the proposed pipe sizing complies with P3005.4.2 and P3002.2. Correct the plans as necessary to demonstrate that the reduced pipe size is adequate for the connected fixture load. |
||
| 07/14/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |