Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0726-03810
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/22/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/21/2026 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0726-03810 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are for the 2024 International Residential Code and 2024 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2024 code compliance. Construction plans require minimum code compliance for approval. Provide a separate response letter addressing each comment with location of change on the plans. SITE PLAN: 1. Remove “the Oro Valley Town” from note #12. PLANS: 1. Provide a Roof Framing Plan with beams sized for supporting live and dead structural loads (Table R602.7(3)), R301.1. Clarify the actual size of the GluLam beam shown at note #7 sheet A1.1. SECTIONS - DETAILS: 1. Show Detail #5 & 6 sheet S1.1 with 1” gap post base hardware or pressure treated posts in contact with concrete, R403.1. 2. Clarify the wall sheathing or stucco surface on Detail #2 sheet S1.1, R106.1.1. Remove any stucco between the ledger and wall studs. ELECTRICAL PLANS: 1. Clarify if the Future Jacuzzi Tub Outlet is included on this permit of a separate permit. The appropriate plans should show the circuit location and size. If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 07/22/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Georgia Pennington, Lead Planner PROJECT: TC-RES-0726-03810 (Porch) (1st Review) TRANSMITTAL DATE: (7/22/26) This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. 1. Provide setback dimensions from the existing porch to the rear and side yard property lines. Additionally, correct required 6' setback line to 5'. 2. Correct General Note 12 to City of Tucson information, instead of Oro Valley. If you have any questions about this transmittal, please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov or at 520-837-6311. |
||
| 07/17/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |