| 07/17/2026 | Residential Building - Standard | APPROVED | |||
| 07/23/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/15/2026 | Addressing Validation | REQUIRES RESUBMIT | For questions: PDSD-Permits@tucsonaz.gov Once this initial review is complete, please resubmit construction documents with full permit address on every page. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf |
||
| 07/23/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Erick Bieber Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0726-03789 8925 E Old Spanish Trail, Tucson, AZ 85710 Residential Addition/Alteration (1st Review) TRANSMITTAL DATE: July 23rd, 2026 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9 & .12. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. (Comment) The site plan appears incomplete. Please show all accessory buildings and shade structures on site. Ensure that their locations are drawn accurately. If structures have been removed, indicate them on the site plan. 2. (Comment) Zoning can not locate permits for a number of accessory buildings and shade structures on site located through aerial imagery. Zoning is unable to approve the accessory storage shed until either a permit is submitted for the unpermitted accessory structures on site, or the accessory structures are added to the scope of work of the current permit. 3. (Comment) The minimum perimeter yard (rear and side) setback in the R-1 zone is 5’. Detached accessory structures built within the perimeter yard setback can be approved with permission from the adjacent property owner using the following statement: My Name is __________________ and I am the owner of the property located at ________________________. I have reviewed the site plan and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ 4. (Comment) Accessory buildings and shade structures or shade sails that are attached to the primary dwelling will require a Design Development Option (DDO) if they are proposed within the required 5’ setback but are 1’ or more away from the property line. If an attached accessory structure and shade structure or shade sail is proposed less than one foot from the property line, a Board of Adjustment Variance will be required for approval. Please reach out to Mark.Castro@tucsonaz.gov for any questions regarding DDOs or the Board of Adjustment Variance process. 5. (Comment) More comments may be forthcoming on the next review based on the submittal of a completed site plan. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov |
||
| 07/15/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |