| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/16/2026 | Residential Building | APPROVED | |||
| 07/27/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/17/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit Activity Number: TC-RES-0726-03781 (1st Review) Project: Single family residence with patio wall Location: 3429 W TINY BIRD CT Review Date: 7/17/2026 Reviewer: Marco Contreras – Engineering Associate - Site Engineering Reviewer Contact: Marco.contreras@tucsonaz.gov Related cases: DP22-0229 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter review time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. Provide a response letter addressing each comment with location of change on the plans. Submit the separate response letter and plan set files. Applicable code links: • https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-3213 - Hillside UDC • https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-10384 - TSM 2 • https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-11798 - TSM 9.1 - Hillside Grading • https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-3917 - UDC 5.7 ERZ Site Engineering Review Comments: The property, located at 3429 W TINY BIRD CT, is located within the QUAIL RIDGE subdivision that falls under as one of the Starr Pass Master Planned Communities. As such additional requirements and permits will be required for all development proposed for this property. QUAIL RIDGE LOT 18 1. The property and subdivision are subject to Hillside Development Zone (HDZ) Design standards. As such, for the new residence, an associated Grading permit (Development Package on TDC) will be required for submission and approval prior to the issuance and approval of any residential building permits. Refer below for grading plan expectations. This is required per the Zoning overlay HDZ for the area. 2. As the property is located within Starr Pass HOA – Approval from the HOA Design board will be required at time of grading permit submission and should be included in resubmission of this current building permit. 3. In accordance with General note #8, an associated floodplain use permit is required for the proposed new development. At time of submission for the grading permit, a floodplain use permit will be submitted on behalf of the applicant internally. 4. At time of submission of the grading permit, ensure to denote the required building floodplain setback & 100-year floodplain limits as found on the Final plat. 5. After historical review of the property information and reviewing DP22-0229 paired with updated imagery, it appears no grading work was completed nor inspected. As such, it shows that DP22-0229 has been expired due to no action being taken. With this in mind, it will be required that a new grading permit be submitted for review & approval. Ensure that all plans are up to date & an applicable geotechnical analysis and review be completed. The Grading plan submittal shall include: • Regulatory Compliance: Demonstrate compliance with TSM 2-01.0.0 and TSM 9-01.0.0 (HDZ standards). • Existing Conditions: Depict existing topography with 1- or 2-foot contour intervals; include benchmark and datum reference (NAVD 88). • Proposed Grading: Show proposed contours and/or spot elevations throughout the site, including finished grade elevations at all building corners, parking areas, and drainage structures. • Limits of Disturbance (LOD): Delineate the full extent of all proposed grading, including all drainage-related improvements. • Cut & Fill Quantities: Provide total area of disturbance (sq. ft.) and total cut and fill volumes (Earthwork Table). • Average Natural Cross Slope (ACS): Provide ACS calculations per TSM 9-01.3.0. • Hillside Drainage Management: Address interceptor drain/swale design per TSM 2-01.10.0 as applicable. • Regulated Area Delineation: Clearly depict the 100-year floodplain limits, Protected Riparian Area (PRA), and Erosion Hazard Setback (EHS) on the grading plan in a surveyable manner. • Engineer of Record: Include signed and sealed Engineer of Record stamp and signature block. SUMMARY OF KEY DESIGN CONSIDERATIONS: ✓ Identify and delineate all regulated areas on submitted plans in a surveyable manner. ✓ Obtain Starr Pass HOA Design Review Board approval prior to grading permit submission. ✓ Engage a licensed Arizona Civil Engineer early in the design process to address HDZ, ERZ, and floodplain requirements. |
||
| 07/23/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston, Planner PROJECT: TC-RES-0726-03781 3429 W Tiny Bird Ct., Tucson, AZ 85745 SFR & Exterior Fence/Wall (1st Review) TRANSMITTAL DATE: 07/23/2026 This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. Add or make the following corrections to Sheet 1: a. Under Lot Info, please make a note that the property lies within the Hillside Development Zone, governed by UDC Article 5. b. UDC Table 6.3-2.A was amended January 1, 2026. Required side and rear setbacks for the R-1 zone are now 5’ for interior lots. The front setback is still 20’. c. Provide the driveway dimensions. d. Apply for a ROW permit under Tuson Development Center Online (https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits ) if work in the ROW is proposed. e. Provide a landscape plan. As of January 1, 2026, a landscape plan is required for all new residential units. Visit the following link for instructions: https://middle-housing-cotgis.hub.arcgis.com/pages/Residential-Landscaping-Code Please make sure to read through the document paying particular attention to the last few paragraphs. 2. The City of Tucson Inclusive Home Design Ordinance requires all new dwellings — including ADUs, single-family residences, and duplexes — to provide an accessible route connecting the public street, sidewalk, or driveway to an accessible entrance of the home. This pathway must be shown, dimensioned, and labeled on the plans. In plain terms: there needs to be a clearly defined, walkable path from where a person arrives (the street, sidewalk, or driveway) all the way to a usable door of the home — one that someone using a wheelchair or mobility aid could navigate without barriers. An exterior accessible route that shall conform to 2017 ICC A117.1 Sections 402 and 403 and City of Tucson Inclusive Home Design Ordinance. Reference: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf Action Items — Show the following on your plans: • Draw and label the path as "Accessible Route" • Provide a minimum clear width of 4 feet with a width call-out on the plans • Note the proposed running slope (must not exceed 5% / 1:20) and cross slope (must not exceed 2% / 1:50) • Identify the accessible entrance the route leads to Acceptable Accessible Route compositions include: • Portland cement concrete (PCC) • Broom Finished concrete • Brick or unit pavers (Only if set on a stable cement base with no gaps exceeding ½”) • Concrete pavers on concrete base (Same joint and evenness requirements as brick) • Flagstone: must be mortared – loose set does not qualify • Any surfaces equivalent in smoothness, hardness, and durability NOTE: Decomposed granite (DG) is not permitted for required accessible routes, even if compacted 3. Upon resubmittal of the site plan, please provide a response letter addressing all review comments provided by staff, the revised site and construction plans. 4. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. The City of Tucson Unified Development Code may be accessed here: www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code . If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov |
||
| 07/27/2026 | Fire New Construction Standard | REVIEW COMPLETED | Meets fire flow requirements with 2 hydrants less than 600 feet away. OK | ||
| 07/16/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |