Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0725-03761
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/18/2025 | Residential Building - Standard | APPROVED | |||
| 08/28/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/22/2025 | Addressing Validation | REQUIRES RESUBMIT | It appears this project is for a Duplex. Units will have to be confirmed and assigned to Permit Application and on ALL documents and plans prior to issuance. Once Zoning approves structure, Contact Pima County Addressing to have units added into system at Addressing@pima.gov or 520-724-9512. Please sign into your TDC account and request a Change of Address to include units and re-submit documents/plans with primary address and unit #'s on all plan sheets. | ||
| 08/28/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0725-03761 5518 E HAWTHORNE ST. – R-1 Repair Fire Damage ADU (1st Review) TRANSMITTAL DATE: August 28, 2025 Provide a detailed response letter with your next submittal that clearly shows how you have addressed all Zoning comments. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) with an accessory dwelling unit (ADU) is a permitted use in this zone (Table 4.8-2). See 4.9.7.B.6, 8, & 9 and 6.6.3. 1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example, to include but not limited to: a. Provide the owners name on the plot plan. b. Provide the legal description, “MITMAN E60' N165' LOT 10 EXC N30' BLK 12” on the plot plan. c. Provide a lot coverage calculation that meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements. d. Show all utility lines on the plot plan. e. Provide a dimension from the centerline of Hawthorne St. to the face of curb and from the face of curb to the north property line. 2. The north/south property dimension is not correct and should be 135’. 3. Remove the reference to “ALLEY” from the plan as there is no right-of-way along the south property line. 4. The “6’-0” B.S.L” shown for the north property line is not correct. Review UDC Article 6.4.5.C.1.a and provide the correct front street perimeter yard setback requirements. 5. The description provided, “Repair Fire Damage ADU” is unclear. Zoning was not able to find an approved permit for an ADU on this parcel. If you are proposing to convert an existing structure to an ADU the following comments apply: a. Per UDC Article 6.6.3.B.6 The minimum side and rear yard setback for an accessory dwelling unit is five feet, proposed perimeter yard setback from the proposed ADU to the west property line is 4’-0”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 07/31/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |