Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0725-03707
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/26/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/13/2025 | Residential Building - Standard | REQUIRES RESUBMIT | Provide a complete plan set including sheet #4 with the next submittal. Include any electrical alterations. | ||
| 08/26/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-RES-0725-03707 8802 E. 27th Street Tucson, AZ 85710 Carport Addition (1st Review) TRANSMITTAL DATE: 8/26/2025 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: The ½ Right of Way is mislabeled on your site plan. Per Paving Improvement Plan I-77-045, the centerline to base of wedge curb is 15’ and from base of wedge curb to property line is 10’. Please update accordingly. https://maps-and-records.tucsonaz.gov/construction-plans/details/I-77-045. 2. Comment: Per UDC 6.4.3.C.1, “Roofed areas, open on at least one side, which provide shelter to exterior areas such as balconies, entrances, stoops, and terraces, provided they are not used for utilities, maintenance, laundry, storage, or motor vehicle parking are excluded from lot coverage calculations.” Please remove the porch from your lot coverage calculations and update the calculations. 3. Comment: Please draw, label, and dimension the front street setback for the new carport to E. 27th Street property line. Your project narrative includes these dimensions however they are not drawn or labeled on your site plan. 4. Comment: Site zoning is unable to approve this building permit until the Design Development Option (DDO) has been approved. Please see below. 5. Comment: The following comments are related to an application for a Design Development Option (DDO) (UDC 3.11.1): The minimum required front street setback in the R-1 zone is 20’ (UDC 6.4.5.C). Based on your project narrative, the proposed front street setback is 14’. The minimum required perimeter yard setback in the R-1 zone is the greater of six (6) feet or two-thirds (2/3) the height of the structures exterior wall facing each interior property line (UDC Table 6.3-2.A). Based on a proposed wall height of 8’ for the new carport, the minimum required setback to the East property line is 6’. The proposed setback to the East property line is 3’. Both of the proposed reduced setbacks (front street and side yard) will require approval through the DDO application process. Please apply for your DDO as a zoning modification sub-record. For information on how to apply for sub-record, please visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf. For additional questions about the DDO process, please reach out to Georgia Pennington at Georgia.Pennington@tucsonaz.gov or Mark Castro at Mark.Castro@tucsonaz.gov. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 07/28/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |