Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0725-03658
Parcel: 128111740

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0725-03658
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/13/2025 Residential Building - Standard APPROVED
08/13/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/13/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Erick Bieber
Planning & Development Services Department – Zoning Review Section

PROJECT: TC-RES-0725-03658
4710 E Cecelia St, Tucson, AZ 85711
Residential Addition/Alteration (1st Review)

TRANSMITTAL DATE: August 13th, 2025

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. (Comment) Please provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example, to include but not limited to:
a. Provide lot line dimensions which can be found on the subdivision plat map at the following link:
https://maps-and-records.tucsonaz.gov/subdivisions/details/1326
b. Provide the legal description of the property, which is “FRANKLIN HEIGHTS LOT 2 BLK 6”
c. Indicate the zoning of the property and of the surrounding properties. This property and its surrounding properties are in the R-1 zone.
d. Provide dimensions for and label all structures on site, including porches.
e. Draw, dimension, and label the vehicular use area. Per Unified Development Code (UDC) definition, this is any area used for the movement, parking, or standing of motor vehicles.
f. Provide lot coverage calculations.
g. Provide a dimension from the centerline of Cecelia St to the face of curb, where asphalt meets the concrete curb (which is 16’ per paving plan I-73-014) and from face of curb to front street property line (which is 14’ per paving plan I-73-014).
h. Provide setback dimensions of the existing dwelling to all applicable property lines.
i. Dimension and label the 50’ Arroyo Chico Drainageway in place of “Back Alley” south of the property.

2. (Comment) Per UDC Table 6.3-2.A, the minimum side and rear yard setbacks are 6’-0” or 2/3 the height of the exterior wall, whichever is greater. Based on the proposed porch with a height of 7’-6”, the required setback would be 6’-0”. The indicated setback for the proposed porch is 3’-4” from the south property line. A Design Development Option (DDO) will be required. Please submit a DDO application under the Zoning Modification sub-record that has been created. For instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf
For additional questions regarding DDOs, contact Mark Castro at Mark.Castro@tucsonaz.gov.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code

For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov
07/23/2025 PDSD Application Completeness Express REVIEW COMPLETED