Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0725-03636
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/19/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/19/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0725-03636 360 E BILBY RD TUCSON Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. COMMENTS: 1. Please show existing receptacles and smoke/Co2 detectors on pg.A2.1 2. Are you using epoxy at the Dowel Bars on pg. A3 connecting to existing slab? If so please clarify. 3. Show where weep screed is being installed on pg. A3 4. Provide roof plan, how are new walls connecting to roof and new roof? Provide section of how roof is extending. Rafters or trusses? 5. What material is being used for interior finish on pg. A3? 6. Per the inclusive home design referenced on pg. A0.0 in Governing codes, provide a detail of how the front door will be ADA accessible, it looks like there will be a drop off from the FFE to the existing concrete. 7. Are you adding any diffusers to make sure the current CFM will adequately heat and cool the added living space? If so please provide the details. Should you have any questions about these comments, I can be reached at Zane.Aouane@tucsonaz.gov |
||
| 08/01/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Olga Salazar Planner PROJECT: TC-RES-0725-03636 360 E BILBY RD TUCSON, AZ 85706 Porch Enclosure (1st Review) TRANSMITTAL DATE: This site is located in the C-2 zone (Unified Development Code (UDC) Article 4.7.21). A single-family residence is a permitted use in this zone (Table 4.8-4) subject to Use Specific Standards 4.9.7.B.6. 1. COMMENT: Residential projects in a C-2 Zone have a lot coverage of 70%. Please provide a lot coverage calculation on your next submittal. 2. COMMENT: The require setback for residential projects adjacent to nonresidential zones is 10 feet. The proposed setback is 7’6’’. A Design Development Option (DDO) is required. Please contact Mark Castro for next steps Mark.castro@tucsonaz.gov. The DDO application is available at the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf. 3. COMMENT: There appears to be discrepancy with the dimensions of the lot provided and the city’s GIS information. There appears to be a small parcel (138-11-002A) that is a part of this site but owned by a different entity. Should the two parcels be combined the DDO referenced in comment #2 might not be necessary. However, lot dimensions must still be verified and corrected. 4. COMMENT: Based on aerial imagery, there are two unpermitted structures on the site. These structures must appear on your site plan fully dimensioned and must meet setbacks. Accessory structures on the front yard are not permitted. If setbacks cannot be met, a neighbor waiver may be utilized to reduced the setbacks of accessory structures. Example of an adjacent owner’s setback waiver for detached accessory structures: The adjacent owner’s waiver statement must be added to the site plan. The following statement can be used. My Name is __________________ and I am the owner of the property located at ________________________. I have reviewed the site plan and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ ************************************************************************************************************ Ejemplo de renuncia de retroceso de un propietario adyacente para chalets estructuras accesorias. Declaración de exención del propietario adyacente debe agregarse al plan de sitio. Puede utilizar la siguiente instrucción. Mi nombre es ________________ y yo soy el dueño de la propiedad ubicada en la _____________________. He revisado el plan y no tengo ninguna objeción a que estructura se encuentra o construye ____________ desde la línea de propiedad, como se muestra en el plan. Firma: ________________________________ Fecha: ________________________________ If you have any questions about this transmittal, please contact Olga Salazar at Olga.Salazar@tucsonaz.gov. |
||
| 07/22/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |