Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-0725-03591
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/29/2025 | Site Engineering - Standard | APPROVED | |||
| 10/13/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/13/2025 | Residential Zoning | PENDING ASSIGNMENT | |||
| 09/08/2025 | Addressing Validation | REQUIRES RESUBMIT | Please reupload the site plan with the correct address on all pages of the site plan. The address on the site plan on pages 3-10 do not match the address on the permit. | ||
| 09/30/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0725-03591 2nd PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings. Show the current code reference on the plans. Update the framing plan notes, sheet A3.0. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. PLANS: 1. Show interior braced wall panels with foundation anchor bolt connection to bottom plates, R602.10.8.3 and R403.1.6. Show the foundation below the interior braced walls on the foundation plan, sheet A2.0. SECTIONS - DETAILS: 1. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. The vent calculation on sheet A3.0 is not appropriate for a building with parapets. Show the location if roof ventilation opens if part of the design or relocate the insulation to the roof underside with an air-impermeable material. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Please contact the plans reviewer if you have any questions: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 09/08/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |