Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0725-03545
Parcel: 107131590

Address:
102 W BIRDMAN DR

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0725-03545
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/16/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/16/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT PDSD Residential Review Section

PROJECT: TC-RES-0725-3545
Replacing 30 gal natural gas WH for 40 gal natural gas water heater.-(1st Review)
(102 W BIRMAN DR)

TRANSMITTAL DATE: July 16th, 2025

Comments:
1. Please verify total length of gas line.
2. The ¾” line pipe is undersized for the given length and total appliance demand(175,000 BTU). Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_piping_sample_060324.pdf

https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_handout_2018_irc_2019.2.4.pdf

Questions email building_official@tucsonaz.gov
07/16/2025 PDSD Application Completeness Express REVIEW COMPLETED