Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0725-03342
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/31/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/31/2025 | Residential Building - Standard | REQUIRES RESUBMIT | 1. Please provide the wall/fence height. 2. Be advised the height can not exceed 7 ft from grade to the top of the wall. 3. If you wish to exceed the 7 feet in height please obtain a registrants approval licensed in Arizona. 4. Please re submit. |
||
| 07/29/2025 | Site Engineering - Standard | REQUIRES RESUBMIT | Permit: TC-RES-0725-03342 Location: 2002 E LA MADERA DR Review Date: 7/29/2025 Site Engineering Comments: 1. This property resides within a recognized FEMA AE Zone Floodplain and will require a Floodplain Use permit. 2. Site Engineering will be requiring that proper flood venting be determined and done to the wall to ensure proper flow to be allowed. The proper flood venting necessary for this area will need to be determined by a hydrologist or certified engineer. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 07/31/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-RES-0725-03342 2002 E. La Madera Dr. Tucson, AZ 85719 Perimeter Wall Height Increase (1st Review) TRANSMITTAL DATE: 7/31/2025 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: There was no wall heights provided on your plans. Please include all proposed wall heights to ensure they meet the height requirements. Per UDC 6.6.2.I, βthe maximum height of a wall or fence within a perimeter yard shall be 6β, but no higher than 10β, if: (See figure 6.6.1-A, Height of Wall or Fence within a side or rear perimeter yard.) a. At least 75% of the area above 6β in height is left unobstructed and open through the use of architectural elements, such as arches, columns, or wrought iron; b. Part of, or located on top of, a retaining wall no higher than ten feet measured from design grade and no higher than six feet measured from the top of the retaining portion of the wall; c. A greater height is required through the rezoning process or the special exception land use process; d. A greater height is required by a specific UDC standard. If the proposed wall exceeds the maximum allowed height of a wall and does not meet the criteria above, a Design Development Option (DDO) can be used to potentially increase the allowed height of the wall. As no wall height was provided, DDO comments cannot be provided at this time. Please reach out to Georgia Pennington at Georgia.Pennington@tucsonaz.gov or Mark Castro at Mark.Castro@tucsonaz.gov if you have questions about the DDO process. If you choose to apply for a DDO, it will be done as a sub-record in your permit. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf. 2. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 07/03/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |