Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0724-04490
Parcel: 136191890

Address:
3211 S MEAD AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.4

Permit Number - TC-RES-0724-04490
Review Name: RESIDENTIAL NEW DWELLING v.4
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/29/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/29/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: TC-RES-0724-04490
3211 S MEAD AV. – R-1
Front Porch (1st Review)

TRANSMITTAL DATE: April 29, 2025

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example, to include but not limited to:
a. The plot plan shall be drawn at an engineering scale, i.e. 1” = 10’, 1” = 20’ and the scale will be clearly indicated on the plan.
b. Provide the owners name on the plot plan.
c. Provide a lot coverage calculation on the plot plan that meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements.
d. Clearly show the proposed porch on the plot plan along with all applicable perimeter yard setback dimensions.
e. Show all utility lines on the plot plan.
f. Provide a dimension from centerline of Mead to the face of curb, where pavements meets the concreate curb, and from face of curb to the west property line. Based on Construction Plan I-62-018, sheet 12A, fount at: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-62-018, the distance from centerline to curb is 16’ and from face of curb to the property line is 9’.
g. Provide the zoning of this parcel and all adjacent parcels on the plot plan.
h. Provide the legal description., “LAKESIDE NO 2 LOT 189” on the plot plan.

2. Provide a full floor plan of the entire house as the requirements of UDC Article 4.9.7.B.7 may apply.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
04/01/2025 PDSD Application Completeness Express REVIEW COMPLETED