Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0724-04287
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/24/2024 | Fire New Construction | NOT REQUIRED | |||
| 08/22/2024 | Site Engineering | NOT REQUIRED | |||
| 08/22/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/29/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0724-04287 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. Provide a response letter on separate file with the updated construction plan set. SITE PLAN: 1. Provide a site plan showing utilities for the dwelling, R106.1.1. Show the location of all utility lines from property line to building(s) along with required alterations. SECTIONS - DETAILS: 1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. Update detail #1 & 2 on sheet SD-2. ELECTRICAL PLANS: 1. Update the Riser Diagram showing sub panel A and B, NEC 225.30, E3403, Table E3704.2(1). 2. Show the location of the new panel A, E3404.13 & E3706.2. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 08/21/2024 | Site Landscape | REQUIRES RESUBMIT | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA PDSD SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: BEDROOM SUITE; GREAT ROOM; LAUNDRY ROOM AND COVERED PORCH ADDITION ACTIVITY NO: TC-RES-0724-04287 ADDRESS/PARCEL: 1137 E BILBY RD/14025107B ZONING: MH-1 MOBILE HOME ZONE This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. Please resubmit revised drawings along with a detailed response letter, which states how all Landscape/NPPO Review Section comments are addressed. SITE LANDSCAPE/NPPO SECTION COMMENTS: 1. Ensure that Zoning and Engineering comments are addressed prior to landscape section approval. 2. Upon review of aerial images of the site, it appears that protected native vegetation may be present on site where the additions to the home are taking place. Please provide an NPPO that provides mitigation for the protected plants that will be disturbed. If there are no viable native plants, or if there are native plants, but they won’t be disturbed, then please provide an NPPO Waiver for the project. If a copy of the NPPO Waiver form is needed for exception, please reach out and I will email a copy for your use. If you have any questions about these comments, I can be reached at chad.keller@tucsonaz.gov |
||
| 08/21/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0724-04287 1137 E BILBY RD. – MH-1 Bedroom Suite; Great Room; Laundry Room and Covered Porch Addition (1st Review) TRANSMITTAL DATE: August 21, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the MH-1 zone (UDC 4.7.10). A single family residence is a permitted use in this zone (Table 4.8-2). 1. Based on aerial photos the 260 SF EXIST PATIO shown at the northeast corner of the EXISTING MAIN HOUSE shows up some time after 2005, Zoning was not able to find approved permit documents for this structure. One of the following is required: 1) Provide approved permit documents for this patio, 2) Provide building plans for this patio and include it in this permit, or 3) Show it to be demolished on this plan. 2. Based on aerial photos the 142 SF EXISTING COVERED PATIO shown at the southeast corner of the EXISTING GUEST HOUSE shows up some time after 2018, Zoning was not able to find approved permit documents for this structure. One of the following is required: 1) Provide approved permit documents for this patio, 2) Provide building plans for this patio and submit a separate permit, or 3) Show it to be demolished on this plan. 3. Based on aerial photos the EXISTING O.H. shown at along the south side of the 704 SF EXISTING STRUCTURE shows up some time after 2022, Zoning was not able to find approved permit documents for this structure. One of the following is required: 1) Provide approved permit documents for this EXISTING O.H., 2) Provide building plans for this EXISTING O.H. and include it in this permit, or 3) Show it to be demolished on this plan. 4. Based on aerial photos there is an addition along the north side of the 704 SF EXISTING STRUCTURE shows up some time after 2014, Zoning was not able to find approved permit documents for this structure. One of the following is required: 1) Provide approved permit documents for this structure, 2) Provide building plans for this structure and include it in this permit, or 3) Show it to be demolished on this plan. 5. Based on aerial photos there is a shed type structure that shows up some time after 2022 cated along the north property line that is not shown on this plan. Zoning was not able to find approved permit/compliance documents for this structure. One of the following is required: 1) Provide approved permit/compliance documents for this structure, 2) Show this structure on the plan along with the size, height and perimeter yard setback and if applicable provide building plans for this structure and include it in this permit, or 3) Show it to be demolished on this plan. It does not appear that this structure meets perimeter yard setbacks to the north property line, 10' or ¾(H) = Height of the proposed exterior building wall, The greater of the two dimensions applies. If the structure does not meet perimeter yard setbacks a minimum a neighbors setback waiver is required, UDC Article 6.6.2.D. To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s): My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 07/23/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |