Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0724-04211
Parcel: 135053010

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0724-04211
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/19/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/19/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0724-04211 (6568 E CALLE MERCURIO TUCSON, AZ 85710)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC).

1. Aerial views of the property show the overhead service conductors will be passing over the roof detached structure. The overhead service conductor over the structure requires an 8’ clearance above the roof, E3604.2.1. The 8’ clearance is required to be maintained for a distance of 3’ from the edge of the roof. Show a mast height necessary to achieve this clearance. Check with TEP customer service for service line options. https://www.tep.com/electric-service-requirements

2. Provide the current service rating and the proposed new service rating, E3602.1.

3. Update the site plan to show the proposed Over Head Electrical line or note if the service will be underground.

4. Correct the site plan to show the location of sub-panel B. There are two sub-panel Cs shown, but no B.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
07/19/2024 PDSD Application Completeness Express REVIEW COMPLETED