Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: In Review
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - TC-RES-0724-04083
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: In Review
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
N/A | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
N/A | Site Engineering | PENDING ASSIGNMENT | |||
N/A | Site Zoning | PENDING ASSIGNMENT | |||
09/17/2024 | Residential Building | REQUIRES RESUBMIT | Show the (carport roof greater than 200 SF) structure with one-hour fire-resistive wall construction parallel with the adjoining (neighboring) property line in compliance with IBC Table 721.1(2) or provide a clear 3’ fire separation distance between the property line and the structure. This construction or separation is required from ground to roof and from end to end of the roof which is a component of the carport rather than a property site wall (fence). The carport may be reduced to 200 SF without requiring a wall as part of the structure. | ||
09/13/2024 | PDSD Application Completeness | REVIEW COMPLETED |